Effects of blood-processing protocols on fetal and total DNA quantification in maternal plasma.

Chiu RW, Poon LL, Lau TK, Leung TN, Wong EM, Lo YM

Publication: Clin Chem (2001) • Vol 47 • Page 1607-13PMID: 11514393View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood processing steps on the quantification of maternal and fetal cell-free DNA in EDTA plasma.

Conclusion

The concentration of beta-globin DNA in plasma was dependent on the method of plasma isolation, but the concentration of sex determining region of the Y chromosome (SRY) in plasma was unaffected by blood processing.

Studies (1)

Purpose

The purpose of this study was to determine the effects of centrifugation, Percoll gradient and filtration steps on the quantification of maternal and fetal cell-free DNA in EDTA plasma. Blood was processed within 2 h of venipuncture. Plasma was stored in polypropylene tubes at -20 degrees C until analysis.

Summary of Findings

When plasma was isolated by centrifugation on a Percoll gradient with no further purification, the concentration of beta-globin DNA was higher than when the plasma was isolated by a single centrifugation at 1600 x g, alone or in combination with a centrifugation at 16000 x g and/or filtration, or when further purified after Percoll gradient by centrifugation at 16000 x g or filtration. Further, significantly higher beta-globin concentrations were found in plasma isolated by centrifugation on a Percoll gradient, with or without further purification, than in plasma isolated by centrifugation at 1600 x g and 16000 x g steps with filtration between the two centrifugations (p<0.05). Significantly higher beta-globin concentrations were also found in plasma isolated by centrifugation at 800 x g without further purification then when plasma was subsequently filtered (p<0.05). When plasma was obtained from the same women on three different days, the standard deviation of the beta-globin concentration was significantly higher in plasma obtained by a single centrifugation at 800 x g than when filtered after centrifugation (p<0.05). However, there was no effect of blood processing protocol on the concentration of SRY in plasma.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Pregnant
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionTime of biospecimen collection
    Day 1
    Day 2
    Day 3
    Biospecimen Aliquots and ComponentsBlood processing method
    Centrifugation
    Centrifugation and filtration
    Percoll-gradiant separation
    Percoll-gradient separation and filtration
    Biospecimen Aliquots and ComponentsCentrifugation
    Different number of centrifugation steps compared
    Multiple speeds compared
    Biospecimen Aliquots and ComponentsFiltration
    0.2 uM filtered
    Unfiltered
    Real-time qPCR SpecificTargeted nucleic acid
    Beta-globin
    SRY