Skip to main content

Use of different anticoagulants in test tubes for analysis of blood lactate concentrations: Part 2. Implications for the proper handling of blood specimens obtained from critically ill patients.

Wiese J, Didwania A, Kerzner R, Chernow B

Publication: Crit Care Med (1997) • Vol 25 • Page 1847-50PMID: 9366768View on PubMed

Purpose

The purpose of this paper was to determine the effects of type of anticoagulant on the measurement of lactate in whole blood and to compare results with levels measured in serum or plasma from healthy volunteers and those with a diagnosis of hyperlactatemia.

Conclusion

Lactate levels measured in sodium citrate whole blood were significantly lower than levels measured in sodium heparin, EDTA, or lithium heparin whole blood. However, there were no significant differences in lactate levels between whole blood containing these three anticoagulants. The authors state that significantly higher levels of lactate were measured in plasma or serum compared to whole blood, regardless of diagnosis, although the difference was slightly more pronounced among hyperlactatemia patients (>2.2 mmol/L lactate).

Studies (1)

Purpose

The purpose of this study was to determine the effects of type of anticoagulant on the measurement of lactate in whole blood and to compare results with levels measured in plasma and serum from healthy volunteers and those with hyperlactatemia. Blood specimens were placed on ice after collection for up to 10 minutes prior to analysis.

Summary of Findings

Lactate levels measured in sodium citrate whole blood were significantly lower than levels measured in sodium heparin, EDTA, or lithium heparin whole blood (p<0.001, all), however, there were no significant differences in lactate levels between whole blood containing these three anticoagulants. The authors state that significantly higher levels of lactate were measured in plasma or serum compared to whole blood, regardless of diagnosis (normal versus hyperlactatemia), although the difference was slightly more pronounced among hyperlactatemia patients (>2.2 mmol/L lactate) than healthy controls.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Other diagnoses
  • Platforms

    Small moleculeIon selective electrode
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Hyperlactatemia
    Normal
    Biospecimen AcquisitionAnticoagulant
    EDTA
    Lithium heparin
    Sodium citrate
    Sodium heparin
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Whole blood