Skip to main content

Why do results conflict regarding the prognostic value of the methylation status in colon cancers? The role of the preservation method.

Tournier B, Chapusot C, Courcet E, Martin L, Lepage C, Faivre J, Piard F

Publication: BMC Cancer (2012) • Vol 12 • Page 12PMID: 22243995View on PubMed

Purpose

The purpose of this paper was to compare methylation levels and bisulfite conversion assay efficacy between case-matched frozen and formalin-fixed, paraffin-embedded (FFPE) colon adenocarcinoma specimens. DNA extraction methods were also compared for FFPE specimens.

Conclusion

The percentage of specimens that generated interpretable results following bisulfite conversion was lower for FFPE specimens (55-67.5%) compared to case-matched frozen controls (87.2-97.4%), and was dependent upon the promoter investigated.  In FFPE specimens, DNA extraction method also influenced the efficacy of bisulfite conversion of the LINE-1 promoter, as a higher percentage of interpretable results were obtained when a FFPE-specific extraction kit was used (75 vs. 55%), although values were still sub-par to frozen controls (95%).  Although data was not shown, the authors note that the poor bisulfate conversion associated with extraction with a conventional kit led to artificially high levels of methylation compared to those observed among specimens extracted with the FFPE-specific kit. Methylation levels also differed between FFPE and frozen specimens, although no trends were observable among promoters. 

Studies (2)

Purpose

The purpose of this study was to compare the efficacy and reliability of bisulfite conversion with pyrosequencing (an assay to quantify and detect DNA methylation) in FFPE specimens extracted using two different kits.  A total of 40 surgically resected colon adenocarcinoma specimens were used. Case-matched specimens were extracted with a conventional magnetic-silica particle based kit (MagnaZorb) and the QIAamp DNA FFPE tissue kit (which includes a 1 h incubation at 90°C), and the percentage of interpretable results was recorded for a single promoter (LINE-1). Assays were run in duplicate for each sample.

Summary of Findings

The efficacy of bisulfite conversion in FFPE specimens was affected by DNA extraction method, as the percentage of interpretable results was lower with the conventional magnetic-silica particle-based kit (55%; MagnaZorb kit by Bionobis) compared to the FFPE-specific kit (75%, QIAamp DNA FFPE tissue kit by Qiagen). Reliability was inferior  among FFPE specimens extracted with a traditional kit when compared to the FFPE-specific extraction kit; 13/40 specimens extracted with the conventional kit displayed different pass/fail results between runs compared to 5/40 specimens extracted with the FFPE-specific kit.   Although data was not shown, the authors note that the poor bisulfate conversion associated with extraction with a conventional kit led to artificially high levels of methylation compared to those observed among specimens extracted with the FFPE-specific kit.

  • Biospecimens

    TissueColorectal
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    DNABisulfite conversion assay
    DNADNA sequencing
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    MagaZorb kit
    QIAamp DNA FFPE Tissue kit (Qiagen)