Skip to main content

Stability of nucleosomal DNA fragments in serum.

Holdenrieder S, Mueller S, Stieber P

Publication: Clin Chem (2005) • Vol 51 • Page 1026-9PMID: 15914786View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage duration and temperature, freeze-thaw cycling, thaw duration and temperature, and mixing protocol on the quantification of nucleosomes in EDTA-stabilized serum.

Conclusion

Up to 144 h of storage of EDTA-stabilized serum at 4 or 25 degrees C had no effect on the levels of nucleosomes. In contrast, when EDTA-stabilized serum was stored at 37 degrees C, the nucleosome yield decreased with increasing storage duration, and a 50% reduction from 1 h levels was noted in serum stored for 24 h. The vortex or rolling duration had no effect on levels of nucleosomes in EDTA-stabilized serum. Up to 3-freeze-thaw cycles only led to small changes (<10%) in nucleosome content, regardless of thaw duration or temperature.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration and temperature, freeze-thaw cycling, thaw duration and temperature, and mixing protocol on the quantification of nucleosomes in EDTA-stabilized serum. EDTA was added to serum after centrifugation and all serum was frozen at -70 degrees C until analysis.

Summary of Findings

Up to 144 h of storage of EDTA-stabilized serum at 4 or 25 degrees C had no effect on the level of nucleosomes. In contrast, when EDTA-stabilized serum was stored at 37 degrees C, the nucleosome yield decreased with increasing storage duration, and a 50% reduction from 1 h levels was noted in serum stored for 24 h. The vortex or rolling duration had no effect on levels of nucleosomes in EDTA-stabilized serum. Up to 3-freeze-thaw cycles only led to small changes (<10%) in nucleosome content, regardless of thaw duration or temperature.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    DNAELISA
    ProteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBiospecimen mixing
    Rolled in overhead roller for 15 min
    Rolled in overhead roller for 30 min
    Vortexed for 10 sec
    Vortexed for 30 sec
    Vortexed for 5 sec
    StorageFreeze/thaw cycling
    1 cycle
    2 cycles
    3 cycles
    StorageStorage duration
    1 h
    144 h
    2 h
    24 h
    3 h
    4 h
    48 h
    6 h
    72 h
    StorageStorage temperature
    25 degrees C
    37 degrees C
    4 degrees C
    StorageThaw duration
    12 h
    2 h
    StorageThaw temperature/condition
    25 degrees C
    4 degrees C