The purpose of this paper was to determine the effects of tissue processing technique on proteomic analysis of formalin-fixed paraffin-embedded (FFPE) tissue specimens.
Impact of routinely employed procedures for tissue processing on the proteomic analysis of formalin-fixed paraffin-embedded tissue.
Bronsert P, Weißer J, Biniossek ML, Kuehs M, Mayer B, Drendel V, Timme S, Shahinian H, Küsters S, Wellner UF, Lassmann S, Werner M, Schilling O
Purpose
Conclusion
There were no significant differences in the numbers of unique peptides identified in FFPE specimens processed by each method and the cryopreserved specimens. The majority of proteins were identified in microwave-based, vacuum/ethanol-based, and xylene-based processing methods and cryopreserved specimens for each tumor. Gene Ontology (GO) profiles were highly similar, and relative protein abundances showed strong to very strong correlations between FFPE specimens processed by any of the three methods and cryopreserved specimens. However, a significantly lower proportion of lysine containing peptides and a significantly higher proportion of arginine containing peptides were found in the FFPE specimens compared to the cryopreserved specimens, but there were no differences between the three FFPE processing methods.
Studies (1)
Purpose
The purpose of this study was to determine the effects of tissue processing technique on proteomic analysis of FFPE tissue specimens. Two primary lung cancer specimens and 3 liver metastases of colorectal cancer were included in this study. Four samples from each tumor were collected. One was snap-frozen in liquid nitrogen and stored at -80°C while the other three were fixed in formalin and processed by a microwave-based Tissue-Tek x 120, a vacuum/ethanol-based Leica PELORIS II, or a xylene-based Shandon Excelsior TM ES. The authors do not provide the exact protocol or reagents used with each one of these processing methods.
Summary of Findings
There were no significant differences in the numbers of unique peptides identified in FFPE specimens processed by each method or the cryopreserved specimens. For each of the 4 differently-processed samples from each of the 5 tumors (20 specimens altogether), 59-75% of the identified proteins (765-1003 total for each specimen/processing combination) were also found in the three other specimens from the same tumor processed by the other methods. GO profiles were highly similar between microwave-based, vacuum/ethanol-based, and xylene-based processing methods and cryopreserved specimens. Relative protein abundances showed strong to very strong correlations between FFPE specimens processed using different methods and cryopreserved specimens (r2=0.744-0.905). Similar levels of semitryptic peptides were found for the three FFPE processing techniques and cryopreserved specimens (4.7-5.7%). While the proportion of oxidized methionine residues was lowest among cryopreserved specimens (2.8%), the three FFPE processing methods led to similar proportions of oxidized methionine containing peptides (3.9-4.5%), and these were not significantly different from the cryopreserved specimens. Importantly, a significantly lower proportion of lysine containing peptides and a significantly higher proportion of arginine containing peptides were found in the FFPE specimens compared to the cryopreserved specimens, but there were no differences between the three FFPE processing methods.
Biospecimens
TissueLiverTissueLungPreservation Types
FormalinFrozenDiagnoses
NeoplasticCarcinomaPlatforms
ProteinColorimetric assayProteinLC-MS or LC-MS/MSPeptideLC-MS or LC-MS/MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Clearing duration/condition Microwave-based Tissue-Tek XpressVacuum/ethanol-based Leica PELORIS IIXylene-based Shandon Excelsior TM ESBiospecimen Preservation Dehydration duration/condition Microwave-based Tissue-Tek XpressVacuum/ethanol-based Leica PELORIS IIXylene-based Shandon Excelsior TM ESBiospecimen Preservation Duration of tissue/ specimen processing Microwave-accelerated tissue processingTraditional tissue processingBiospecimen Preservation Embedding duration/condition Microwave-based Tissue-Tek XpressVacuum/ethanol-based Leica PELORIS IIXylene-based Shandon Excelsior TM ESBiospecimen Preservation Type of fixation/preservation Formalin (buffered)Snap frozen