Skip to main content

Measurement of plasma viscosity by free oscillation rheometry: imprecision, sample stability and establishment of a new reference range.

Pedersen L, Nielsen EB, Christensen MK, Buchwald M, Nybo M

Publication: Ann Clin Biochem (2013) • Vol 51 • Page 495-498PMID: 24081187View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage and patient gender on plasma viscosity.

Conclusion

Storage of plasma at 20 degrees C for 48 h, 4 degrees C for 20 days, or -20 degrees C for 3 months did not affect viscosity. There was no effect of patient gender on plasma viscosity.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage and patient gender on plasma viscosity. EDTA plasma from 20 healthy patients was stored at -20 degrees C for 3 months. After thawing specimens at 37 degrees C, plasma was then stored at 4 degrees C for 20 days, 20 degrees C for 2 days, or analyzed immediately. Reference ranges for plasma viscosity were based on plasma obtained from 585 Danish blood donors.

Summary of Findings

Storage at 20 degrees C for 48 h, 4 degrees C for 20 days, or -20 degrees C for 3 months did not affect plasma viscosity. There was no effect of patient gender on plasma viscosity.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    MorphologyRheometer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient gender
    Female
    Male
    StorageStorage duration
    2 days
    20 days
    3 months
    StorageStorage temperature
    -20 degrees C
    20 degrees C
    4 degrees C