The purpose of this paper was to determine the effects of room temperature storage with agitation on levels of clotting factors in apheresis platelet concentrates (APC).
von Willebrand factor, clotting factors, and clotting inhibitors in apheresis platelet concentrates.
Weiss DR, Franke D, Strasser EF, Ringwald J, Zimmermann R, Eckstein R
Purpose
Conclusion
While all analytes except antithrombin were significantly affected by storage of APC, only prothrombin time (PT), activated partial thromboplastin time (aPTT), Protein S activity and antigen and Factor XII (FXII) antigen were outside of the reference ranges after room temperature storage.
Studies (1)
Purpose
The purpose of this study was to determine the effects of room temperature storage with agitation on levels of clotting factors in APC. APC were collected into acid-citrate dextrose at a 1:10 ratio. All APC used in this study were rejected for clinical use for reasons the authors state were not expected to impact hemostasis. After experimental storage, all supernatants were frozen at -40 degrees C and analyzed together.
Summary of Findings
Compared to APC stored for 0 days, APC stored at room temperature for 4 days had prolonged PT and aPTT, higher levels of fibrinogen, Factor FXI, FXII activity, FXII antigen, von Willebrand Factor (vWF) antigen, and vWF ristocetin cofactor (RCo), and lower levels of factors II, V, VII, VIII, IX, and X, Protein C activity, Protein S activity and Protein S antigen (p<0.05, all). Free Protein S antigen in APC decreased with room temperature storage, reaching significance compared to day 0 on day 7. Levels of antithrombin in APC were unaffected by room temperature storage. Importantly, by day 4 of room temperature storage, the average PT exceeded the reference range, and Protein S activity and antigen levels were below the reference range. Further, in some units, aPTT exceeded the reference range by day 4 despite the average aPTT remaining within the reference range, and FXII antigen exceeded the reference range at all time points including day 0. All other analytes remained within the reference ranges throughout storage. The vWF multimers ratios shifted to more low molecular weight vWF during storage.
Biospecimens
FluidBloodPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
Cell count/volumeHematology/ auto analyzerGlycoproteinHematology/ auto analyzerMorphologyHematology/ auto analyzerPeptideClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerProteinColorimetric assayProteinHematology/ auto analyzerProteinELISAPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Time at room temperature 0 days4 days5 days7 days