Skip to main content

Vitamin B6 in plasma - sample stability and the reference limits.

Panton KK, Farup PG, Sagen E, Sirum UF, Asberg A

Publication: Scand J Clin Lab Invest (2013) • Vol 73 • Page 476-9PMID: 23819643View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage duration and temperature and patient gender on levels of the B6 vitamer pyridoxal-5'-phosphate (p-PLP) in EDTA-plasma.

Conclusion

Generally, p-PLP was stable in EDTA-plasma for 24 h at room temperature or 4-8 degrees C, but a lower value was detected in 1 of 6 specimens after 4 h at room temperature and after 24 h at 4-8 degrees C. p-PLP concentration was 4 nmol/L higher in males than females, but the difference was not significant.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration and temperature and patient gender on levels of p-PLP in EDTA-plasma. All specimens were protected from light during storage. Following experimental storage, specimens were frozen at -80 degrees C until analysis.

Summary of Findings

Generally, p-PLP was stable in EDTA-plasma for 24 h at room temperature or 4-8 degrees C, but a lower value was detected in 1 of 6 specimens after 4 h at room temperature and after 24 h at 4-8 degrees C. p-PLP concentration was 4 nmol/L higher in males than females, but the difference was not significant.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    Small moleculeHPLC
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient gender
    Female
    Male
    StorageStorage duration
    1 h
    2 h
    24 h
    4 h
    8 h
    StorageStorage temperature
    22-24 degrees C
    4-8 degrees C