Plasma Processing Conditions Substantially Influence Circulating microRNA Biomarker Levels.
Cheng HH, Yi HS, Kim Y, Kroh EM, Chien JW, Eaton KD, Goodman MT, Tait JF, Tewari M, Pritchard CC
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of plasma centrifugation steps, filtration of PPP and frozen storage of plasma prior to additional processing on platelet counts and levels of miRNA. K2EDTA plasma and serum were aliquoted and frozen at -80 degrees C before analysis. miRNA was extracted using miRNeasy and frozen at -80 degrees C until analysis using real-time qPCR arrays and individual real-time qPCR assays. Plasma and platelet rich plasma (PRP) were obtained by centrifugation at 3400 x g or 600 x g, respectively. Additional plasma specimens were frozen at -80 degrees C for up to 6 years before centrifugation at 1940 x g for 10 min to produce PPP.
Summary of Findings
Centrifugation of plasma at 1940 x g for 10 min to produce PPP removed 80-90% of the platelets in fresh plasma or plasma that had been stored at -80 degrees C for up to 6 years before centrifugation. When PPP was then filtered, >99% of the platelets in the initial plasma were removed. PRP produced by centrifugation at 600 x g, instead of the 3400 x g used for standard plasma, had 13-19 fold more platelets than standard plasma. Along with platelet removal, a non-significant decline in microparticle counts was observed. The numbers of miRNAs detected in platelet concentrates, PRP, standard plasma, PPP, and filtered PPP were 315, 325, 277, 279, and 262, respectively. Of the 282 miRNAs detected in multiple specimen types, 72% were expressed differentially between specimen types, with 10% differing by 4-30 fold, 46% by 30-1000 fold and 15% by more than 1000 fold. miR-142-3p, let-7a, miR-233 and miR-16 were highly affected by plasma processing steps, but miR-451 and miR-122 were only minimally affected by plasma processing steps, and this was true regardless of whether or not plasma was stored for up to 6 years at -80 degrees C before additional centrifugation steps. Importantly, the rank order of miRNA expression was significantly different between standard plasma and filtered PPP (p<0.0001). The miRNAs most affected by plasma processing were moderately correlated with the miRNA most highly expressed in platelets (r=0.43, p<0.0001).
Biospecimens
FluidPlasmaPreservation Types
FrozenNone (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeCoulter counterCell count/volumeHematology/ auto analyzerRNAReal-time qRT-PCRRNALow density arrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaPlatelet-poor plasmaPlatelet-rich plasmaPlateletsBiospecimen Aliquots and Components Centrifugation Different number of centrifugation steps comparedMultiple durations comparedBiospecimen Aliquots and Components Filtration 0.22 uM filteredUnfilteredBiospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Real-time qRT-PCR Specific Targeted nucleic acid let7amiR-122miR-124miR-16miR-205miR-210miR-233miR-251miR-92a
Purpose
The purpose of this study was to determine the effects of filtration on platelet counts and levels of miRNA in serum and to compare miRNA profiles in serum and plasma. Serum and plasma were aliquoted and frozen at -80 degrees C before analysis. miRNA was extracted using miRNeasy and frozen at -80 degrees C until analysis using real-time qPCR arrays and individual real-time qPCR assays.
Summary of Findings
Filtration removed microparticles from serum but only slightly decreased the platelet counts. 6% of miRNAs were differentially expressed by more than 4 fold between filtered and unfiltered serum. Specifically, the authors show miR-142-3p and let-7a were affected by filtration, and miR-223, miR-16, and miR-122 were unaffected by filtration of the serum. 6% of miRNAs were differentially expressed between serum and plasma.
Biospecimens
FluidPlasmaFluidSerumPreservation Types
FrozenDiagnoses
NormalPlatforms
Cell count/volumeCoulter counterCell count/volumeHematology/ auto analyzerRNAReal-time qRT-PCRRNALow density arrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaSerumBiospecimen Aliquots and Components Filtration 0.22 um filteredUnfilteredReal-time qRT-PCR Specific Targeted nucleic acid let7amiR-122miR-142-3pmiR-16miR-233miR-451