Effects of immediate or delayed addition of platelet additive solution on the in vitro quality of apheresis platelets.

Ringwald J, Tully S, Geier C, Hauck B, Weiss D, Callaert M, Eckstein R

Publication: Transfusion (2012) • Vol 52 • Page 1237-44PMID: 22070790View on PubMed

Purpose

The purpose of this paper was to determine the effects of delaying addition of modified platelet (Plt) additive solution III (PAS-IIIM) by 2 h to hyperconcentrated Plts on markers of Plt quality during subsequent storage at room temperature.

Conclusion

Delaying the addition of PAS-IIIM to Plts by 2 h generally did not impact levels of markers of Plt quality, but the partial pressure oxygen (pO2) was higher on day 5 of room temperature storage of Plts when PAS-IIIM was added 2 h after collection rather than immediately after collection.

Studies (1)

Purpose

The purpose of this study was to determine the effects of delaying addition of PAS-IIIM by 2 h to hyperconcentrated Plts on markers of Plt quality during subsequent storage at room temperature. Plts were collected by cytapheresis into two bags, and PAS-IIIM was automatically added immediately to one of the TA-citrated storage bags of Plts while the other was stored for 2 h at room temperature before manual addition of PAS-IIIM. After collection, hyperconcentrated Plts or Plts in PASIII-M were stored for the first 30 min without agitation, but subsequent storage was on a flatbed shaker.

Summary of Findings

Delaying the addition of PAS-IIIM to Plts by 2 h led to comparable levels of magnesium, potassium, phosphate, albumin, total protein, and glucose and lactate consumption to Plts to which PAS-IIIM was added immediately following collection. Hypotonic shock response (HSR), extent of shape change (ESC), and partial pressure carbon dioxide (pCO2) declined slightly during subsequent room temperature storage, regardless of whether PAS-IIIM addition to Plts was delayed or not. Similarly, the percentage of Plts expressing P-selectin, pH and lactate levels increased during storage, regardless of when PAS-IIIM was added. The pO2 was higher on day 5 of room temperature storage of Plts when PAS-IIIM was added 2 h after collection rather than immediately after collection (p<0.05).
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Cell count/volumeHematology/ auto analyzer
    Cell count/volumeLight microscopy
    Cell count/volumeFlow cytometry
    Electrolyte/MetalClinical chemistry/auto analyzer
    MorphologyFlow cytometry
    MorphologyMacroscopic observation
    PeptideClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    ProteinHematology/ auto analyzer
    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    1 day
    5 days
    7 days
    StorageTime at room temperature
    0 h
    2 h