Comparative in vitro evaluation of apheresis platelets stored with 100% plasma or 65% platelet additive solution III/35% plasma and including periods without agitation under simulated shipping conditions.
Moroff G, Kurtz J, Seetharaman S, Skripchenko A, Awatefe H, Thompson-Montgomery D, Myrup A, Wagner SJ
Purpose
The purpose of this paper was to determine the effects of storage duration, storage solution, method of adding solution and disruptions in continuous agitation on markers of quality in apheresis platelets (Plts).
Conclusion
Plt concentration and mean Plt volume (MPV) were unaffected by room temperature storage duration, storage solution or disruptions in agitation, regardless of cell counter used. During room temperature storage, pH, the percentage of discoid Plts (%disc), the extent of shape change (ESC) and partial pressure carbon dioxide (PCO2) declined, and partial pressure oxygen (PO2) increased. PCO2, pH, %disc, ESC, hypotonic shock response (HSR), and PCO2 were significantly lower and the percentage of Plts expressing CD62P was significantly higher in Plts stored in 65% PAS-III/35% plasma than those stored in 100% plasma. Percentage aggregation, percent surface covered, and aggregate size tended to be lower after room temperature storage of Plts in 65% PAS-III than those in 100% plasma, but the differences were not significant. PO2 and lactate were comparable between storage solutions, but glucose was lower in Plts in 65% PAS-III, which the authors attribute to the absence of glucose in PAS-III. A 24 h disruption in continuous agitation on day 2-3 in Plts stored in 65% PAS-III did not significantly affect Plt content, pH, %disc, ESC, HSR, PO2, PCO2 or the percentage of Plts expressing CD62P. However, disruptions in continuous agitation did accentuate some of the observed storage solution differences. The authors report that manual versus automated addition of PAS-III had no effect on any analytes.
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage duration, storage solution, method of adding solution and disruptions in continuous agitation on markers of quality in apheresis Plts. Plts were collected using an amicus separator and a 10:1 acid citrate dextrose (ACD) to blood ratio. When specimens were not being continuously agitated, they were placed in shipping boxes and maintained at room temperature.
Summary of Findings
Plt concentration and MPV were unaffected by room temperature storage duration, storage solution or disruptions in agitation, regardless of cell counter used. During room temperature storage, pH, %disc, ESC and PCO2 declined, and PO2 increased. PCO2, pH, %disc, ESC, HSR, and PCO2 were significantly lower, and the percentage of Plts expressing CD62P was significantly higher in Plts stored in 65% PAS-III/35% plasma than those stored in 100% plasma. Percentage aggregation, percent surface covered, and aggregate size tended to be lower after room temperature storage of Plts in 65% PAS-III than those stored in 100% plasma, but the differences were not significant. PO2 and lactate were comparable between storage solutions, but glucose was lower in Plts in 65% PAS-III which the authors attribute to the absence of glucose in PAS-III. A 24 h disruption in continuous agitation on day 2-3 in Plts stored in 65% PAS-III did not significantly affect Plt content, pH, %disc, ESC, HSR, PO2, PCO2 or the percentage of Plts expressing CD62P. However, disruptions in continuous agitation did accentuate some of the observed storage solution differences. The authors report that manual versus automated addition of PAS-III had no effect on any of the analytes.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
CarbohydrateClinical chemistry/auto analyzerCell count/volumeHematology/ auto analyzerGasClinical chemistry/auto analyzerSmall moleculepHSmall moleculeClinical chemistry/auto analyzerMorphologyLight scatteringMorphologyLight microscopyMorphologyMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Short-term storage solution 100% plasma65% PAS-III/35% plasmaAutomated additionManual additionStorage Storage conditions Continuous agitationNot agitated between day 2 and 3Not agitated for 24 h on day 2-3Not agitated for 4 h on day 0 and 8 h each on day 1 and 3Not agitated for 7-8 h on day 0 and 24 h on day 2-3Storage Time at room temperature 1 day2 days5 daysHematology/ auto analyzer Specific Technology platform Cell Dyn 3700XE-2100D