Comparative in vitro evaluation of apheresis platelets stored with 100% plasma or 65% platelet additive solution III/35% plasma and including periods without agitation under simulated shipping conditions.

Moroff G, Kurtz J, Seetharaman S, Skripchenko A, Awatefe H, Thompson-Montgomery D, Myrup A, Wagner SJ

Publication: Transfusion (2012) • Vol 52 • Page 834-43PMID: 22014086View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage duration, storage solution, method of adding solution and disruptions in continuous agitation on markers of quality in apheresis platelets (Plts).

Conclusion

Plt concentration and mean Plt volume (MPV) were unaffected by room temperature storage duration, storage solution or disruptions in agitation, regardless of cell counter used. During room temperature storage, pH, the percentage of discoid Plts (%disc), the extent of shape change (ESC) and partial pressure carbon dioxide (PCO2) declined, and partial pressure oxygen (PO2) increased. PCO2, pH, %disc, ESC, hypotonic shock response (HSR), and PCO2 were significantly lower and the percentage of Plts expressing CD62P was significantly higher in Plts stored in 65% PAS-III/35% plasma than those stored in 100% plasma. Percentage aggregation, percent surface covered, and aggregate size tended to be lower after room temperature storage of Plts in 65% PAS-III than those in 100% plasma, but the differences were not significant. PO2 and lactate were comparable between storage solutions, but glucose was lower in Plts in 65% PAS-III, which the authors attribute to the absence of glucose in PAS-III. A 24 h disruption in continuous agitation on day 2-3 in Plts stored in 65% PAS-III did not significantly affect Plt content, pH, %disc, ESC, HSR, PO2, PCO2 or the percentage of Plts expressing CD62P. However, disruptions in continuous agitation did accentuate some of the observed storage solution differences. The authors report that manual versus automated addition of PAS-III had no effect on any analytes.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration, storage solution, method of adding solution and disruptions in continuous agitation on markers of quality in apheresis Plts. Plts were collected using an amicus separator and a 10:1 acid citrate dextrose (ACD) to blood ratio. When specimens were not being continuously agitated, they were placed in shipping boxes and maintained at room temperature.

Summary of Findings

Plt concentration and MPV were unaffected by room temperature storage duration, storage solution or disruptions in agitation, regardless of cell counter used. During room temperature storage, pH, %disc, ESC and PCO2 declined, and PO2 increased. PCO2, pH, %disc, ESC, HSR, and PCO2 were significantly lower, and the percentage of Plts expressing CD62P was significantly higher in Plts stored in 65% PAS-III/35% plasma than those stored in 100% plasma. Percentage aggregation, percent surface covered, and aggregate size tended to be lower after room temperature storage of Plts in 65% PAS-III than those stored in 100% plasma, but the differences were not significant. PO2 and lactate were comparable between storage solutions, but glucose was lower in Plts in 65% PAS-III which the authors attribute to the absence of glucose in PAS-III. A 24 h disruption in continuous agitation on day 2-3 in Plts stored in 65% PAS-III did not significantly affect Plt content, pH, %disc, ESC, HSR, PO2, PCO2 or the percentage of Plts expressing CD62P. However, disruptions in continuous agitation did accentuate some of the observed storage solution differences. The authors report that manual versus automated addition of PAS-III had no effect on any of the analytes.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Cell count/volumeHematology/ auto analyzer
    GasClinical chemistry/auto analyzer
    Small moleculepH
    Small moleculeClinical chemistry/auto analyzer
    MorphologyLight scattering
    MorphologyLight microscopy
    MorphologyMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageShort-term storage solution
    100% plasma
    65% PAS-III/35% plasma
    Automated addition
    Manual addition
    StorageStorage conditions
    Continuous agitation
    Not agitated between day 2 and 3
    Not agitated for 24 h on day 2-3
    Not agitated for 4 h on day 0 and 8 h each on day 1 and 3
    Not agitated for 7-8 h on day 0 and 24 h on day 2-3
    StorageTime at room temperature
    1 day
    2 days
    5 days
    Hematology/ auto analyzer SpecificTechnology platform
    Cell Dyn 3700
    XE-2100D