Purpose
The purpose of this study was to determine the effects of type of anticoagulant, storage temperature and duration before storage at -80 degrees C, and extraction method on the quality and quantity of DNA from blood. Blood processed within 30 min of collection was not frozen before DNA extraction, but all other blood specimens were frozen at -80 degrees C.
Summary of Findings
The MagNA Pure LC automated extraction procedure yielded a higher average DNA concentration and a higher purity than the manual QIAamp DNA blood mini kit or in-house procedures, as determined by 260/280 nm absorbance ratios. The authors used the MagNA Pure LC automated extraction method for the anticoagulant and storage experiments. In general, storage of blood specimens at room temperature or 4 degrees C led to decreases in DNA yield over time, with greater decreases in specimens stored at room temperature than 4 degrees C (p<0.05). The greatest decreases in DNA yield after blood storage were observed in specimens collected in 68 IU of lithium heparin, while the smallest yield decreases were observed in specimens collected in sodium citrate. Gel electrophoresis revealed an increase in low-molecular weight DNA extracted from blood stored at room temperature compared to blood stored at 4 degrees C. Fragments up to 2258 bp in length were amplifiable using DNA from specimens stored at either temperature and those collected in all anticoagulants, except lithium heparin. None of the 3 DNA fragments (126 bp, 570 bp, or 2258 bp) was amplified using DNA from blood collected in 68 or 60 IU lithium heparin stored <30 min, but with longer storage of lithium heparin blood at room temperature or 4 degrees C, the fragments were mostly amplifiable. Generally, real time qPCR results were not different between specimens stored at room temperature and those stored at 4 degrees C. However, there were significant differences in crossing point (Cp) values between the different anticoagulants, with specimens collected in lithium heparin having the highest average Cp values.
Biospecimens
FluidBloodPreservation Types
FrozenNone (Fresh)Diagnoses
NormalPlatforms
DNAElectrophoresisDNASpectrophotometryDNAPCRDNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant Citrate-theophylline-adenosine-dipyridamoleFluoride-oxalateLithium heparinMultiple concentrations evaluatedPotassium EDTASodium citrateStorage Storage duration 168 h24 h30 min48 h6 h72 h96 hStorage Storage temperature 4 degrees CRoom temperatureAnalyte Extraction and Purification Analyte isolation method In-house salt precipitationMagNA Pure LCQIAamp DNA blood mini kitPCR Specific Length of gene fragment 126 bp2258 bp570 bpReal-time qPCR Specific Targeted nucleic acid Adenomatous Polyposis Coli gene