Skip to main content

Effects of anticoagulant, processing delay, and assay method (branched DNA versus reverse transcriptase PCR) on measurement of human immunodeficiency virus type 1 RNA levels in plasma.

Kirstein LM, Mellors JW, Rinaldo CR Jr, Margolick JB, Giorgi JV, Phair JP, Dietz E, Gupta P, Sherlock CH, Hogg R, Montaner JS, Muñoz A

Publication: J Clin Microbiol (1999) • Vol 37 • Page 2428-33PMID: 10405379View on PubMed

Purpose

The purpose of this paper was to determine the effects of anticoagulant type, delayed processing, and assay method on levels of human immunodeficiency virus type 1 (HIV-1) RNA in plasma.

Conclusion

HIV-1 RNA decayed more rapidly in heparinized blood than EDTA blood when left at room temperature before centrifugation. However, there were no significant differences between specimens from the Multicenter AIDS Cohort Study (MACS) which were collected in heparin tubes, generally centrifuged within 6 h of collection, and assayed by branch DNA assay after being frozen for 10 years, and specimens from the British Columbia Drug Treatment Program (BCDTP) which were collected in EDTA or acid citrate dextrose (ACD) tubes, centrifuged within 2 h, and assayed by RT-PCR immediately.

Studies (2)

Purpose

The purpose of this study was to determine the effects of anticoagulant type, delayed processing, and assay method on levels of HIV-1 RNA in plasma. After experimental room temperature storage, aliquoted plasma was frozen at -70 degrees C until analysis.

Summary of Findings

HIV-1 RNA declined by 24% and 11% after a 6 hour delay before centrifugation in heparinized blood, as measured by branch DNA assay and RT-PCR, respectively. After an 18 h delay before processing, the declines reached 46% and 29% for the branch DNA assay and RT-PCR, respectively, in heparinized blood. HIV-1 RNA loss was not significant in EDTA blood after a 6 hour processing delay, but after an 18 h delay, 19% of the HIV-1 RNA was lost, as measured by both the branch DNA assay and by RT-PCR.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    AIDS/HIV-related
  • Platforms

    RNABranch DNA assay
    RNART-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Potassium EDTA
    Sodium heparin
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageTime at room temperature
    0-3 h (2 h)
    15-27 h (18 h)
    3-9 h (6 h)
    Branch DNA assay SpecificTechnology platform
    RT-PCR