The purpose of this study was to determine the effects of storage at room temperature before cooling and the speed at which RCCs were cooled to 4 degrees C on markers of RCC quality during refrigerated storage. RCCs were prepared in saline-adenine-glucose-mannitol (SAGM) by in-line leukoreduction of whole citrate-phosphate-dextrose (CPD) blood. Fast-cooling consisted of placing blood in a refrigerator, while slow cooling consisted of placing blood with climate packs in polystyrene boxes which were then placed in the refrigerator.
Summary of Findings
Cooling the RCCs to 4 degrees C over 10-24 h (slow) as to within 2.5 h (fast) or delaying cooling by storing RCCs at room temperature for as long as 24 h did not lead to any clinically relevant changes in pH, PCO2, hemolysis rate, or levels of lactate, 2,3 DPG, ATP and glucose on day 1 of refrigerated storage. Further, while subsequent refrigerated storage led to decreased pH, glucose, and 2,3 DPG levels, and increased PCO2, hemolysis and lactate levels, these changes were generally larger and first observed at an earlier time point when the RCCs were cooled slower or left at room temperature longer before cooling, but by day 42, meaningful differences between the groups were no longer present. Similarly, the initial rise in ATP levels observed on day 2 or 3 of refrigerated storage was larger in RCCs cooled to 4 degrees C more slowly and those left at room temperature longer, but the subsequent decline in ATP levels was also faster in slowly cooled or room temperature stored RCCs, and by day 42, the levels were comparable between groups.
Biospecimens
CellRed Blood CellsPreservation Types
Other PreservativeDiagnoses
Not specifiedPlatforms
Small moleculeClinical chemistry/auto analyzerProteinHematology/ auto analyzerCell count/volumeHematology/ auto analyzerGasClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Cooling or freezing method/ rate Cooling slowed by insulationRefrigeratorStorage Storage duration 1 day14 days2 days28 days3 days35 days42 daysStorage Time at room temperature 0 h12 h18 h24 h6 h