Systematical evaluation of the effects of sample collection procedures on low-molecular-weight serum/plasma proteome profiling.
Hsieh SY, Chen RK, Pan YH, Lee HL
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of patient fasting, collection tube type, anticoagulant, clotting time and temperature, hemolysis, and centrifugation speed (1500 x g versus 3000 x g) and time (15 or 30 min) on serum and plasma low molecular weight proteome profiles by MALDI-TOF MS with magnetic bead fractionation. All blood was collected using a single venipuncture. Mechanical hemolysis was induced in a subset of specimens, but the authors do not describe how.
Summary of Findings
Out of 101 defined spectral peaks, only 4 and 5 were significantly different between spectra from serum collected after an overnight fast and those from serum collected 2 and 3 h after breakfast, respectively. Out of 105 defined spectral peaks, 22 were significantly different between spectra from serum collected in plain tubes and those from serum collected in serum separator tubes (SST). With increasing clotting times at 4 degrees C or room temperature, coefficients of variation (CVs) >20% were observed in 64% and 66% of spectral peaks for serum, respectively. The authors state that increasing time before centrifugation for plasma specimens similarly increased the CV of a majority of spectral peaks. Significant differences in protein profiles were observed between plasma anticoagulated with heparin, EDTA, sodium citrate and serum. 21% of defined peaks were significantly different between serum with and without mechanically induced hemolysis, and in general, hemolysis led to additional low molecular weight peaks. Centrifugation time (15 min versus 30 min) and speed (1500 x g versus 3000 x g) had minimal effects on serum proteome profiles, with each only leading to significant differences in 4% of defined spectral peaks.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinMALDI-TOF MSPeptideMALDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant EDTAHeparinNoneSodium citrateBiospecimen Acquisition Time of biospecimen collection Collection 2 h after breakfastCollection 3 h after breakfastCollection after overnight fastBiospecimen Acquisition Type of collection container/solution Plain serum tubeSSTBiospecimen Aliquots and Components Blood and blood products PlasmaSerumBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedMultiple durations comparedMultiple speeds comparedBiospecimen Aliquots and Components Hemolysis AbsentPresentStorage Storage duration 1 h12 h24 h6 hStorage Storage temperature 25 degrees C4 degrees C
Purpose
The purpose of this study was to determine the effects of storage temperature and duration as well as freeze-thaw cycling of serum and plasma on low molecular weight proteome profiling by MALDI-TOF MS with magnetic bead fractionation.
Summary of Findings
Storage of serum or plasma at 25 degrees C or 4 degrees C for up to 6 h prior to analysis led to only minimal changes in spectra, and storage for 24 h at these temperatures led to CVs of >20% for serum in 17% and 13% of spectral peaks, respectively and CVs of >20 % for plasma in 32% and 14% of spectral peaks, respectively. Storage of serum or plasma at 4 degrees C for 48 or 96 h led to a larger degree of change among spectra. Storage of serum at -80 degrees C for 3 months did not significantly affect spectral profiles nor did up to 10 freeze-thaw cycles. Freeze-thaw cycling effects were not investigated in plasma.
Biospecimens
FluidPlasmaFluidSerumPreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinMALDI-TOF MSPeptideMALDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Freeze/thaw cycling 0 cycles1 cycle10 cycles3 cycles5 cyclesStorage Storage duration 0 h1 month10 h2 h24 h3 months4 h48 h6 h8 h96 hStorage Storage temperature -80 degrees C25 degrees C4 degrees C