Influence of blood collection systems on the prothrombin time and international sensitivity index determined with human and rabbit thromboplastin reagents.

van den Besselaar AM, Hoekstra MM, Witteveen E, Didden JH, van der Meer FJ

Publication: Am J Clin Pathol (2007) • Vol 127 • Page 724-9PMID: 17439830View on PubMed

Purpose

The purpose of this paper was to determine the effects of type of collection tube, thromboplastin reagent, and analyzer on prothrombin time (PT) and international sensitivity index (ISI) in plasma from patients treated with vitamin K antagonists and untreated individuals.

Conclusion

PT, PT ratios, and ISI were generally significantly affected by collection tube type, although there was some variability with regard to which thromboplastin reagent was used. The authors hypothesize that the higher calcium and magnesium concentrations in the sodium citrate solution in the Vacutainer tubes compared to the S-Monovette and Venosafe tubes were the cause of the PT and ISI differences.

Studies (1)

Purpose

The purpose of this study was to determine the effects of type of collection tube, thromboplastin reagent, and analyzer on PT and ISI in plasma from patients treated with vitamin K antagonists and untreated individuals. Plasma was kept at room temperature for less than 6 hours prior to analysis.

Summary of Findings

Regardless of the thromboplastin reagent or the analyzer used, plasma specimens collected in Vacutainers had significantly shorter average PT and PT ratios than those collected in Venosafe or S-Monovette tubes. Specimens collected in Venosafe tubes had significantly different (some longer and some shorter) average PT and PT ratios from those collected in S-Monovette tubes for all reagents except Thromborel-S (Sysmex CA-1500 analyzer). ISI was significantly different between nearly all collection container pairs for each thromboplastin reagent except between Venosafe and S-Monovette tubes using the Hepato Quick or Thromborel-S reagents. International normalized ratios (INRs) calculated using crossover ISI (from a different tube type) resulted in differences of up to 10%. The authors hypothesize that the higher calcium and magnesium concentrations in the sodium citrate solution in the Vacutainer tubes compared to the S-Monovette and Venosafe tubes were the cause of the PT and ISI differences.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
    Normal
  • Platforms

    MorphologyHematology/ auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Multiple concentrations evaluated
    Sodium citrate
    Biospecimen AcquisitionType of collection container/solution
    Plastic S-Monovette tube
    Polyethylene terephthalate Venosafe tube
    Siliconized glass Vacutainer
    Hematology/ auto analyzer SpecificReaction solution
    Hepato Quick
    Innovin
    Neoplastin Plus
    Simplastin HTF
    Thromborel-S
    Hematology/ auto analyzer SpecificTechnology platform
    Coag-A-Mate MAX
    STA-R
    Sysmex CA-1500