Skip to main content

Preanalytical storage does not affect 99th percentile cardiac troponin T concentrations measured with a high-sensitivity assay.

Gillis JM, Dunselman P, Jarausch J, de Jong N, Cobbaert CM

Publication: Clin Chem (2013) • Vol 59 • Page 442-3PMID: 23220225View on PubMed

Purpose

The purpose of this paper was to determine the effects of delayed blood processing and storage of plasma and serum on levels of cardiac troponin T (cTnT1).

Conclusion

cTnT1 levels in serum or lithium heparin plasma were not affected by storage of whole blood for up to 5 h before processing (longest duration examined). Further, there was no effect of storage of plasma or serum at room temperature, 2-8 degrees C, or -20 degrees C on cTnT1 levels. cTnT1 levels were comparable in lithium heparin plasma and serum.

Studies (1)

Purpose

The purpose of this study was to determine the effects of delayed blood processing and storage of plasma and serum on levels of cTnT1 in blood from patients with suspected myocardial damage. Blood was collected into Venosafe serum tubes or lithium heparin gel tubes. Blood was processed immediately or after storage at room temperature for 3 or 5 h, and the plasma and serum were frozen. Additional plasma and serum specimens were stored at room temperature for 1, 2, 6 or 24 h, 2-8 degrees C for 1, 2, 6 or 24 h, or -20 degrees C for 24 h, 1 week, 4 weeks, or 3 months, after which all specimens were frozen at -80 degrees C for 3 months.

Summary of Findings

cTnT1 levels in serum or lithium heparin plasma were not affected by storage of whole blood for up to 5 h before processing (longest duration examined). Further, there was no effect of storage of plasma or serum at room temperature, 2-8 degrees C, or -20 degrees C on cTnT1 levels. cTnT1 levels were comparable in lithium heparin plasma and serum.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Cardiovascular Disease
    Not specified
  • Platforms

    PeptideClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    0 h
    1 h
    1 week
    2 h
    24 h
    3 h
    3 months
    4 weeks
    5 h
    6 h
    StorageStorage temperature
    -20 degrees C
    -80 degrees C
    2-8 degrees C
    Room temperature