Evaluation of overnight hold of whole blood at room temperature before component processing: effect of red blood cell (RBC) additive solutions on in vitro RBC measures.
Van der Meer PF, Cancelas JA, Cardigan R, Devine DV, Gulliksson H, Sparrow RL, Vassallo RR, de Wildt-Eggen J, Baumann-Baretti B, Hess JR
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of a 24-26 h versus <8 h delay in blood processing and blood processing method on markers of blood quality and red blood cell quality during refrigerated storage. Blood was collected and pooled from 4 donors at 9 different centers. To isolate blood components, 2 centers used the PRP method, 6 centers used the BC method and 1 center used a filtration method. 5/6 centers using the BC method also actively cooled blood to room temperature, but neither of the centers using the PRP method actively cooled blood to room temperature. RBCs were refrigerated in SAGM, and plasma was stored at -30 degrees C.
Summary of Findings
Blood kept at room temperature for 24-26 h had 6% more Plts (p<0.01), a higher hematocrit (p<0.01), lower 2,3 DPG (p<0.001) and a higher percentage of Plts expressing CD62P than blood stored for 8 h (p<0.01). The BC from blood stored for 24-26 h had 20-25% more Plts (p<0.001), 25% more white blood cells (p<0.001) and a lower percentage of Plts expressing CD62P (p<0.01) than the buffy coat from blood stored for 8 h. Plasma volumes were slightly lower when blood was stored for 24-26 h instead of 8 h, but the effect was only significant when blood was processed using the PRP-method. RBCs from blood stored for 24-26 h had lower 2,3 DPG, regardless of storage solution, than RBCs from blood processed within 8 h and stored in SAGM (p<0.001). RBCs from blood kept at room temperature for 24-26 h had higher levels of ATP before refrigerated storage than RBCs from blood processed within 8 h. During storage of RBCs, the differences in ATP and 2,3 DPG content between RBCs from blood processed within 8 h or after 24-26 h were eliminated by day 42 and 21, respectively. At various isolation method-dependent time points, pH was lower and hemolysis rates were higher in blood processed after 24-26 h than within 8 h. The authors report that processing of blood by the PRP method rather than BC method had no effect on RBC parameters.
Biospecimens
FluidBloodCellRed Blood CellsPreservation Types
None (Fresh)FrozenOther PreservativeDiagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeFlow cytometrySmall moleculeHPLCSmall moleculeEnzyme assayGasClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerCarbohydrateEnzyme assayProteinSpectrophotometryElectrolyte/MetalIon selective electrodePre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation FrozenNone (fresh)RefrigerationStorage Short-term storage solution ErythroSol-4PAGGSMSAGMStorage Storage duration 21 days35 days42 days49 days7 daysStorage Time at room temperature 24-26 h<8 h
Purpose
The purpose of this study was to determine the effects of blood storage solution and refrigerated storage on markers of RBC quality. Blood from 4 donors was collected and pooled at 9 different centers. To isolate blood components, 2 centers used the PRP method, 6 centers used the BC method and 1 center used a filtration method. 5/6 centers using the BC method also actively cooled blood to room temperature, but neither of the centers using the PRP method actively cooled blood. RBCs were stored refrigerated in SAGM.
Summary of Findings
During refrigerated storage of RBCs, 2,3 DPG and pH declined and hemolysis rate increased throughout the storage period, while ATP increased initially but then declined. ATP content was highest in RBCs refrigerated in ErythroSol-4 (both methods), or on day 1 when they were stored in SAGM (PRP method). Generally, 2,3DPG levels were similar between storage solutions, but 2,3DPG levels were significantly higher in RBCs stored in ErythroSol on day 7 then in SAGM or PAGGSM after the same refrigerated storage duration. During the first 21 days of storage, RBCs in PAGGSM or ErythroSol-4 had lower pH than specimens stored in SAGM. The hemolysis rates were higher for RBCs stored in SAGM than those stored in PAGGSM or Eythrosol-4, and RBCs isolated by the PRP method generally had a higher rate of hemolysis when stored PAGGSM than ErythroSol-4. The authors report that RBC storage solution had no effects on the levels of potassium, glucose, lactate, oxygen, carbon dioxide, or bicarbonate during refrigerated storage of RBCs.
Biospecimens
FluidBloodCellRed Blood CellsPreservation Types
Other PreservativeDiagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeFlow cytometrySmall moleculeHPLCSmall moleculeEnzyme assaySmall moleculeClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerCarbohydrateEnzyme assayProteinSpectrophotometryElectrolyte/MetalIon selective electrodePre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Filtration Buffy coat methodFiltered whole bloodPlatelet rich plasma methodStorage Short-term storage solution ErythroSol-4PAGGSMSAGMStorage Storage duration 21 days35 days42 days49 days7 days