Mitochondrial dysfunction of platelets stored in first- and second-generation containers is, in part, associated with elevated carbon dioxide levels.

Skripchenko A, Myrup A, Thompson-Montgomery D, Awatefe H, Wagner SJ

Publication: Transfusion (2011) • Vol 51 • Page 371-9PMID: 20796252View on PubMed

Purpose

The purpose of this paper was to determine the effects of platelet (PLT) storage container on markers of PLT quality and mitochondrial function.

Conclusion

During storage of PLTs at room temperature over the course of 7 days, partial pressure oxygen (PO2), hydrogen peroxide fluorescence and the percentages of Annexin V and CD62P positive PLTs increased, and partial pressure carbon dioxide (PCO2), pH, mitochondrial reducing power (MRP), and mitochondrial membrane potential (MMP) decreased. Storage container specific effects were observed for PO2, pH, MRP, PCO2, MMP, intracellular superoxide indicator (ISOA), percentages of CD62P and annexin V positive PLTS, glucose consumption rate and lactate production rate. However, the authors found the many of the differences between specimens stored in PL146 bags and those in CLX bags were only observed in a subset of specimens, with only the differences in pH, pCO2 and PO2 between bag types observed in all specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of PLT storage container on markers of PLT quality and mitochondrial function. Blood was collected in CP2D and stored for 4 h at room temperature before isolation of the platelet rich plasma and leukoreduction. PLT-rich plasma was transferred into either a 300 mL CLX bag or a 600 mL PL146 bag. PLTs were stored at 20-24 degrees C on a reciprocal agitator.

Summary of Findings

Over the course of 7 days at room temperature, PO2, hydrogen peroxide fluorescence and the percentages of Annexin V and CD62P positive PLTs, increased, and PCO2, pH, MRP, and MMP, as determined by the percentage of JC-1 positive PLTs, decreased. On day 1, PO2, pH, and MRP were higher, and PCO2 was lower in specimens stored at room temperature in PLX146 bags than CLX bags. However, by day 4 of room temperature storage, the effect of storage container on MRP had disappeared, and the effects of storage container on PO2 and pH were no longer apparent by day 5 and 7, respectively. In contrast, PCO2 was lower in PLTs stored in PLX146 bags than CLX bags throughout the storage period. During room temperature storage, MMP decreased in specimens stored in PL-146 bags, but not CLX bags, with significant differences between MMP in PLTs in CLX and PL-146 bags apparent by day 4 of storage. Further, the percentages of ISOA, CD62P and Annexin V positive PLTs increased during room temperature storage of PLTs in PL146 bags, but not CLX bags, with significant differences between containers first apparent on day 6, day 5 and day 7, respectively. The glucose consumption rate and lactate production rate of PLTs in PL146 bags was higher than those in CLX bags (p=0.0002 and p=0.0007, respectively). While specimen pH, pCO2 and PO2 were dependent on storage container in all specimens, the authors found that only a subset of specimens stored in PL146 bags had observable differences in the other analytes compared to those stored in CLX bags.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Small moleculepH
    Small moleculeFlow cytometry
    Small moleculeClinical chemistry/auto analyzer
    Cell count/volumeSpectrophotometry
    Cell count/volumeFlow cytometry
    Cell count/volumeHematology/ auto analyzer
    GasClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageTime at room temperature
    1 day
    4 days
    5 days
    6 days
    7 days
    StorageType of storage container
    First-generation PL146 bag
    Second generation CLX bag