Mitochondrial dysfunction of platelets stored in first- and second-generation containers is, in part, associated with elevated carbon dioxide levels.
Skripchenko A, Myrup A, Thompson-Montgomery D, Awatefe H, Wagner SJ
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of PLT storage container on markers of PLT quality and mitochondrial function. Blood was collected in CP2D and stored for 4 h at room temperature before isolation of the platelet rich plasma and leukoreduction. PLT-rich plasma was transferred into either a 300 mL CLX bag or a 600 mL PL146 bag. PLTs were stored at 20-24 degrees C on a reciprocal agitator.
Summary of Findings
Over the course of 7 days at room temperature, PO2, hydrogen peroxide fluorescence and the percentages of Annexin V and CD62P positive PLTs, increased, and PCO2, pH, MRP, and MMP, as determined by the percentage of JC-1 positive PLTs, decreased. On day 1, PO2, pH, and MRP were higher, and PCO2 was lower in specimens stored at room temperature in PLX146 bags than CLX bags. However, by day 4 of room temperature storage, the effect of storage container on MRP had disappeared, and the effects of storage container on PO2 and pH were no longer apparent by day 5 and 7, respectively. In contrast, PCO2 was lower in PLTs stored in PLX146 bags than CLX bags throughout the storage period. During room temperature storage, MMP decreased in specimens stored in PL-146 bags, but not CLX bags, with significant differences between MMP in PLTs in CLX and PL-146 bags apparent by day 4 of storage. Further, the percentages of ISOA, CD62P and Annexin V positive PLTs increased during room temperature storage of PLTs in PL146 bags, but not CLX bags, with significant differences between containers first apparent on day 6, day 5 and day 7, respectively. The glucose consumption rate and lactate production rate of PLTs in PL146 bags was higher than those in CLX bags (p=0.0002 and p=0.0007, respectively). While specimen pH, pCO2 and PO2 were dependent on storage container in all specimens, the authors found that only a subset of specimens stored in PL146 bags had observable differences in the other analytes compared to those stored in CLX bags.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Small moleculepHSmall moleculeFlow cytometrySmall moleculeClinical chemistry/auto analyzerCell count/volumeSpectrophotometryCell count/volumeFlow cytometryCell count/volumeHematology/ auto analyzerGasClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Time at room temperature 1 day4 days5 days6 days7 daysStorage Type of storage container First-generation PL146 bagSecond generation CLX bag