Skip to main content

Factors affecting the risk of blood bank specimen hemolysis.

Tanabe P, Kyriacou DN, Garland F

Publication: Acad Emerg Med (2003) • Vol 10 • Page 897-900PMID: 12896895View on PubMed

Purpose

The purpose of this paper was to determine the effects of patient age and gender, use of a needle versus IV catheter, anatomical site of blood draw, hospital department where collection was performed, needle gauge, and IV catheter gauge on hemolysis rates in plasma specimens.

Conclusion

The use of IV catheters rather than steel needles, smaller IV catheter sizes (18 or 20-24 gauge versus 14-16 gauge), and blood collection from a non-anticubital site were each associated with increased risk for hemolysis. Patient age, gender, hospital department performing blood draw, and needle gauge had no effect on hemolysis rate.

Studies (1)

Purpose

The purpose of this study was to determine the effects of patient age and gender, use of a needle versus IV catheter, anatomical site of blood draw, hospital department where blood draw was performed, needle gauge, and IV catheter gauge on hemolysis rates in plasma specimens evaluated by the presence of a pink to red color.

Summary of Findings

Neither patient age nor gender influenced specimen hemolysis rates. There were no significant differences in the rates of hemolysis between specimens obtained in the emergency department and those obtained in the labor and delivery department. The relative risk for hemolysis significantly increased when IV catheters were used, as opposed to steel needles, and when IV catheter size decreased beyond the 14-16 gauge size, but there was no significant change in the relative risk for hemolysis between specimens collected with different needle gauges. Collection of blood from a non-anticubital site was also associated with a significantly higher relative risk for hemolysis compared to collection of blood from an anticubital site.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    MorphologyMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    <65 years old
    >65 years old
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen AcquisitionAnatomical location of blood draw
    Anticubital vein
    Non-anticubital vein
    Biospecimen AcquisitionCannulation
    14-16 gauge catheter
    18 gauge catheter
    20-24 gauge catheter
    Biospecimen AcquisitionMethod of fluid acquisition
    IV catheter
    Needle
    Biospecimen AcquisitionNeedle gauge
    18 gauge
    19 gauge
    21 gauge
    23 gauge