Skip to main content

In vitro storage characteristics of platelet concentrates suspended in 70% SSP+(TM) additive solution versus plasma over a 14-day storage period.

Saunders C, Rowe G, Wilkins K, Holme S, Collins P

Publication: Vox Sang (2011) • Vol 101 • Page 112-21PMID: 21414010View on PubMed

Purpose

The purpose of this paper was to determine the effects of room temperature storage duration and storage solution on markers of platelet (Plt) function, activation and apoptosis.

Conclusion

Plt concentration, hypotonic shock response (HSR), extent of shape change (ESC), partial pressure carbon dioxide (PCO2), bicarbonate, glucose levels, percentage of Plts staining for CD62P, and mitochondrial membrane potential (MMP) declined, and lactate, partial pressure oxygen (PO2), soluble CD62P levels and percentage of Plts staining for Annexin V increased with room temperature storage. ATP concentrations increased, and the percentage of Plts staining for CD62P decreased during the initial 3-6 days of room temperature storage, but then these analytes decreased and increased, respectively. Changes in Plt concentration and pH were accelerated in specimens stored at room temperature in 70% SSP+ rather than plasma. Plts stored in SSP+ maintained swirling effect, while some Plts stored in plasma showed decreased swirling effect. Glucose, PCO2, bicarbonate, and percentage of plts staining for Annexin V were lower, and lactate, soluble CD62P and MMP were higher in Plts stored in SSP+ than plasma at most time-points.

Studies (1)

Purpose

The purpose of this study was to determine the effects of room temperature storage duration and storage solution on Plt function, activation and apoptosis. Plt concentrates were prepared by the buffy coat method on day 1 from whole blood donations. After leukoreduction, platelet concentrates were stored at room temperature on a horizontal agitator.

Summary of Findings

Plt concentration, HSR, ESC, PCO2, bicarbonate, glucose levels, percentage of Plts staining for CD62P, and MMP declined, and lactate, PO2, soluble CD62P levels and percentage of Plts staining for Annexin V increased with room temperature storage. ATP concentrations increased, and the percentage of Plts staining for CD62P decreased during the initial 3-6 days of room temperature storage, but then these analytes decreased and increased, respectively. Changes in Plt concentration and pH were accelerated in specimens stored at room temperature in 70% SSP+ rather than plasma. Plts stored in SSP+ maintained swirling effect, while some Plts stored in plasma showed decreased swirling effect during the storage period. Glucose, PCO2, bicarbonate, and percentage of Plts staining for Annexin V were lower, and lactate, soluble CD62P and MMP were higher in Plts stored in SSP+ than plasma at most time-points.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    MorphologyMacroscopic observation
    MorphologyHematology/ auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    Small moleculeBioassay
    Cell count/volumeFlow cytometry
    ProteinELISA
    CarbohydrateClinical chemistry/auto analyzer
    GasClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageShort-term storage solution
    Plasma
    SSP+
    StorageTime at room temperature
    1 day
    10 days
    14 days
    2 days
    3 days
    6 days
    8 days