Hemolysis of coagulation specimens: a comparative study of intravenous draw methods.
Stauss M, Sherman B, Pugh L, Parone D, Looby-Rodriguez K, Bell A, Reed CR
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of using extension tubing connected to an IV catheter during blood collection and patient anticoagulant therapy on hemolysis rates among coagulation specimens.
Summary of Findings
While some patients in this study were on anticoagulant therapy and others were not, there was no significant difference in rates of hemolysis between specimens from the two groups. There was also no significant difference in the rates of hemolysis (>0 mg/dL) between specimens collected with the use of extension tubing (33%) and without the use of extension tubing (33%).
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
MorphologyMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Other drugs Anticoagulant therapyNo anticoagulant therapyBiospecimen Acquisition Cannulation Extension tubingNo extension tubing