Storage of buffy-coat-derived platelets in additive solution: in vitro effects on platelets of the air bubbles and foam included in the final unit.

Sandgren P, Saeed K

Publication: Blood Transfus (2011) • Vol 9 • Page 182-8PMID: 21084001View on PubMed

Purpose

The purpose of this paper was to determine the effects of air bubbles in platelets (plts) during room temperature storage on plt quality.

Conclusion

While plt counts and mean platelet volume (MPV) were stable in plts stored at room temperature without air bubbles, plt counts and MPV decreased progressively in plts stored with air bubbles. Compared to 2 days of storage, a slight increase was noted in lactate dehydrogenase (LDH) levels after 7 days of room temperature storage without air bubbles. However, a much larger increase in LDH levels was observed after 5 or 7 days of storage with air bubbles. pH was unaffected by room temperature storage of plts, with or without air bubbles. Partial pressure carbon dioxide (pCO2), bicarbonate and adenosine triphosphate (ATP) levels decreased with room temperature storage of plts and were lower on day 7 in specimens stored with air bubbles than those stored without. The partial pressure oxygen (PO2) increased during room temperature storage of specimens without air bubbles and the PO2 was significantly higher in specimens stored with air bubbles than those without, but PO2 decreased between day 2 and 5 in specimens with air bubbles. Hypotonic shock response (HSR) and extent of shape change (ESC) decreased with storage and were lower in plts stored with air bubbles than those stored without air bubbles. The percentage of CD62P expressing plts increased and CD42b expressing plts decreased during storage, and significantly fewer CD42b expressing plts and significantly more CD62P expressing plts were observed by day 5 and 7, respectively, in specimens stored with air bubbles than those stored without. The percentages of CD41, CD61 and glycoprotein IIb/IIIa (GPIIb/IIIa) expressing plts were unaffected by storage with or without air bubbles. The authors report that swirling effect remained at acceptable levels throughout room temperature storage of plts.

Studies (1)

Purpose

The purpose of this study was to determine the effects of air bubbles during room temperature storage of plts on plt quality. Buffy coats with plasma were prepared from citrate-phosphate-dextrose (CPD)/saline-adenine-glucose-mannitol (SAG-M) blood and stored overnight before isolation of plts. After isolation air bubbles and foam were excluded from one of each sample pairs while the other was stored with the air bubbles and foam. Plts were stored at room temperature on a flat bed agitator and sampled aseptically.

Summary of Findings

While plt counts and MPV were stable in plts stored without air bubbles, plt counts and MPV decreased progressively in plts stored with air bubbles. Compared to plts stored for 2 days, a slight increase was noted in LDH levels after 7 days of room temperature storage without air bubbles, but a much larger increase was observed after 5 or 7 days of room temperature storage with air bubbles. pH was unaffected by room temperature storage of plts, with or without air bubbles. pCO2, bicarbonate and ATP levels decreased with room temperature storage of plts and were lower on day 7 in specimens stored with air bubbles than those stored without. The PO2 increased during room temperature storage of specimens without air bubbles and the PO2 was significantly higher in specimens stored with air bubbles than those without, but PO2 decreased between day 2 and 5 in specimens with air bubbles. HSR and ESC decreased during room temperature storage of plts and were lower in specimens stored with air bubbles than those stored without air bubbles. The percentage of CD62P expressing plts increased and CD42b expressing plts decreased during storage, and significantly fewer CD42b expressing plts and significantly more CD62P expressing plts were observed by day 5 and day 7, respectively, in specimens stored with air bubbles than those stored without. The percentages of CD41, CD61 and GPIIb/IIIa expressing platelets were unaffected by room temperature storage, with or without air bubbles. The authors report that swirling effect remained at acceptable levels throughout room temperature storage of plts.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    Cell count/volumeFlow cytometry
    ProteinSpectrophotometry
    MorphologyMacroscopic observation
    MorphologyHematology/ auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    Small moleculeBioassay
    GasClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage conditions
    With air bubbles
    Without air bubbles
    StorageTime at room temperature
    2 days
    5 days
    7 days