Skip to main content

Effects of whole blood storage on hemoglobin a1c measurements with five current assay methods.

Rohlfing CL, Hanson S, Tennill AL, Little RR

Publication: Diabetes Technol Ther (2012) • Vol 14 • Page 271-5PMID: 22032202View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage duration and temperature and assay type on levels of hemoglobin A1c (HbA1c) in blood specimens from 5 individuals..

Conclusion

HbA1c levels in whole blood were stable for at least 6 days at -20 degrees C, 14 days at 4 degrees C, and 4 days at room temperature, but the timepoint at which levels changed enough to declare instability was assay dependent. HbA1c was only stable for 1 day or less at 30 or 37 degrees C.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration and temperature and assay type on levels of HbA1c in EDTA whole blood from 5 individuals. EDTA whole blood had initial values of 5-10% HbA1c. Stability was defined as within 3 standard deviations of all levels measured in specimens stored at -70 and a less than 0.2% change from previous time-point.

Summary of Findings

Whole blood HbA1c levels were stable at -20 degrees C for at least 80 days when measured by the Siemans DCA 2000+, 10 days when measured by the Tosoh G7, 7 days when measured by Tosoh G8, 42 days when measured by Trinity Biotech ultra, and 6 days when measured by the BioRad Variant II. HbA1c levels were stable in whole blood stored at 4 degrees C for 28 days when measured by the Siemans DCA 2000+, 21 days when measured by the Tosoh G7 or G8, 42 days when measured by Trinity Biotech ultra, and 14 days when measured by the BioRad Variant II. HbA1c levels were stable in whole blood stored at room temperature for 14 days when measured by the Siemans DCA 2000+, 6 days when measured by the Tosoh G7 or G8, 9 days when measured by Trinity Biotech ultra, and 4 days when measured by the BioRad Variant II. However, HbA1c levels were only stable in whole blood stored for 1 day or less at 30 degrees C when measured by the Siemans DCA 2000+, the Tosoh G7 or G8, or the BioRad Variant II, but HbA1c was stable for 3 days at 30 degrees C when measured by the Trinity Biotech ultra. Further, HbA1c levels were stable in whole blood stored 1 day or less at 37 degrees C, regardless of assay type. An extra peak, before the HbA1c peak, began to appear in specimens subjected storage and evaluated by the Tosoh assays, and the peak was visible even in specimens with stable HbA1c levels.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)FrozenOther Preservative
  • Diagnoses

    Not specified
  • Platforms

    ProteinHPLC
    ProteinHematology/ auto analyzer
    ProteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    Refrigeration
    StorageStorage duration
    0 days
    1 day
    10 days
    14 days
    2 days
    21 days
    28 days
    3 days
    4 days
    42 days
    56 days
    6 days
    7 days
    84 days
    StorageStorage temperature
    -20 degrees C
    -70 degrees C
    30 degrees C
    37 degrees C
    4 degrees C
    Room temperature
    Hematology/ auto analyzer SpecificTechnology platform
    BioRad Variant
    Siemens DCA 2000+
    Tosoh G7
    Tosoh G8
    Trinity Biotech Ultra