Skip to main content

Observational study to determine factors associated with blood sample haemolysis in the emergency department.

Ong ME, Chan YH, Lim CS

Publication: Ann Acad Med Singapore (2008) • Vol 37 • Page 745-8PMID: 18989489View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood collection technique on the rates of hemolysis among blood specimens.

Conclusion

Of 227 blood specimens, 19.8% were hemolyzed. Specimen hemolysis was not significantly affected by any of the preanalytical factors analyzed including needle gauge, operator, perceived rate of blood flow, difficulty of collection, sample volume, sample processing interval, or use of IV catheter versus venipuncture. However, use of a vacutainer system, as opposed to a syringe draw, was associated with a higher rate of hemolysis.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood collection technique on the rates of hemolysis among blood specimens. Personnel performing each blood collection filled out a standard questionnaire immediately following collection which included questions about perceived rate of blood flow (fast, moderate, or slow) and perceived difficulty of venipuncture/cannulation (easy, moderate, or hard). Various staff performed the collections including consultants, registrars, medical officers, students, or nurses.

Summary of Findings

Of the 227 blood specimens with completed questionnaires, 19.8% were hemolyzed. Specimen hemolysis was not significantly affected by any of the preanalytical factors analyzed including needle gauge, operator, perceived rate of blood flow, difficulty of collection, sample volume, sample processing interval, or use of IV catheter versus venipuncture. However, use of a vacutainer system, as opposed to a syringe draw, was associated with a higher rate of hemolysis.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Artery
    Vein
    Biospecimen AcquisitionMethod of fluid acquisition
    Blood flow rates compared
    Difficult blood draw
    IV catheter
    Not a difficult blood draw
    Syringe draw
    Vacuum tube
    Venipuncture
    Biospecimen AcquisitionNeedle gauge
    21 gauge or lower
    >21 gauge
    Biospecimen Aliquots and ComponentsAliquot size/volume
    A range of blood collection volumes
    StorageTime at room temperature
    A range of collection to processing intervals