Primary hemostatic capacity of whole blood: a comprehensive analysis of pathogen reduction and refrigeration effects over time.
Pidcoke HF, McFaul SJ, Ramasubramanian AK, Parida BK, Mora AG, Fedyk CG, Valdez-Delgado KK, Montgomery RK, Reddoch KM, Rodriguez AC, Aden JK, Jones JA, Bryant RS, Scherer MR, Reddy HL, Goodrich RP, Cap AP
Purpose
Conclusion
Studies (3)
Purpose
Summary of Findings
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeFlow cytometryMorphologyHematology/ auto analyzerProteinHematology/ auto analyzerProteinELISAGlycoproteinHematology/ auto analyzerPeptideHematology/ auto analyzerCarbohydrateClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood processing method PRT treatedUntreatedStorage Storage conditions PRT-treatedUntreatedStorage Storage duration 0 days1 day14 days2 days21 days3 days4 days5 days6 days7 daysStorage Storage temperature 22 degrees C4 degrees CHematology/ auto analyzer Specific Reaction solution ADPArachidonic acidCollagenHigh ristocetinLow ristocetinTRAP-6
Purpose
The purpose of this study was to determine the effects of storage temperature and PRT-treatment on coagulation markers in plasma. Blood was collected in CPD, and half of the specimens were PRT treated in illumination bags by the addition of riboflavin and exposure to UV light. Specimens were then transferred to storage bags which were stored in metal lined storage containers at each temperature and sampled aseptically.
Summary of Findings
Factor V, VIII, and protein C in plasma decreased with storage of whole blood (p<0.001). Larger decreases in Factor V and VIII levels were noted in PRT-treated specimens than untreated specimens (p<0.001, both), and larger decreases in protein C and factor VIII were observed with storage of blood at room temperature than 4 degrees C (p<0.001 and p=0.036, respectively). Fibrinogen decreased initially in PRT treated specimens (p<0.001), but storage did not have a significant effect, and all levels were within the normal range. Antithrombin III decreased with storage of blood at room temperature (p<0.001), with insignificantly larger changes noted in PRT treated specimens than untreated specimens. von Willebrand factor levels were not affected by PRT-treatment or storage of blood specimens.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
ProteinHematology/ auto analyzerGlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood processing method PRT treatedUntreatedBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage conditions PRT-treatedUntreatedStorage Storage duration 0 days14 days7 daysStorage Storage temperature 22 degrees C4 degrees C
Purpose
Summary of Findings
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeFlow cytometryProteinHematology/ auto analyzerMorphologyHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood processing method PRT treatedUntreatedStorage Storage conditions PRT-treatedUntreatedStorage Storage duration 0 days1 days10 days14 days2 days21 days3 days4 days5 days6 days7 daysStorage Storage temperature 22 degrees C4 degrees C