Evaluation of the properties of components prepared and stored after holding of whole blood units for 8 and 24 hours at ambient temperature.

Moroff G, AuBuchon JP, Pickard C, Whitley PH, Heaton WA, Holme S

Publication: Transfusion (2011) • Vol 51 Suppl 1 • Page 7S-14SPMID: 21223290View on PubMed

Purpose

The purpose of this paper was to determine the effects of room temperature blood processing delays and refrigerated storage on markers of red blood cell (RBC), platelet, and platelet poor plasma quality in specimens from healthy individuals.

Conclusion

After 42 days of storage at 4 degrees C, RBCs from blood processed after a 24 h delay had comparable levels of adenosine triphosphate (ATP), supernatant potassium, and hemolysis as well as comparable pH to specimens processed within 8 h of collection that had been stored for 42 days at 4 degrees C. However, 2,3- diphosphoglycerate acid (DPG) levels were lower in RBCs obtained from specimens with a 24 h processing delay compared to an 8 h processing delay after 42 days storage. Further, there was no effect of blood processing delays on platelet volume, platelet content, pH, recovery from hypotonic stress, supernatant lactate dehydrogenase (LDH), morphology score, or ATP content in platelets stored for 5 days at 20-24 degrees C. After storage of platelet poor plasma at -18 degrees C for an unspecified duration factor V levels were comparable between specimens obtained from blood with 8 and 24 h processing delays, but factor VIII levels were significantly lower in specimens processed with a 24 h delay than those processed after an 8 h delay.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood processing delays and storage on markers of RBC, platelet, and platelet poor plasma quality in healthy individuals. Two blood specimens from each donor were collected at least 70 days apart into citrate-phosphate dextrose with Adsol in the satellite bag and were randomly assignment to the 8 h or 24 h processing delay group. After the assigned processing delay, RBCs were placed in the refrigerator and stored for 42 days, platelets were stored at 20-24 degrees C with agitation for 5 days, and platelet poor plasma was stored at -18 degrees C for an unspecified time.

Summary of Findings

After 42 days of storage at 4 degrees C, RBCs from blood processed after a 24 h delay had comparable levels of ATP, supernatant potassium, and hemolysis as well as comparable pH to specimens processed within 8 h of collection that had been stored for 42 days at 4 degrees C. However, after 42 days refrigerated storage, 2,3-DPG levels were lower in RBCs obtained from specimens with a 24 h processing delay compared to an 8 h processing delay (p<0.05). Further, there was no effect of blood processing delays on platelet volume, platelet content, pH, recovery from hypotonic stress, supernatant LDH, morphology score, or ATP content in platelets stored for 5 days at 20-24 degrees C. After storage of platelet poor plasma at -18 degrees C for an unspecified duration, factor V levels were comparable between specimens obtained from blood with 8 and 24 h processing delays, but factor VIII levels were significantly lower in specimens processed with a 24 h delay than those processed after an 8 h delay (p<0.001).

  • Biospecimens

    CellRed Blood Cells
    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)FrozenOther Preservative
  • Diagnoses

    Normal
  • Platforms

    Electrolyte/MetalFlame emission photometry
    MorphologyHematology/ auto analyzer
    Small moleculeBioassay
    Small moleculeClinical chemistry/auto analyzer
    Small moleculeSpectrophotometry
    ProteinSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    Refrigeration
    StorageTime at room temperature
    24 h
    8 h