Nursing blood specimen collection techniques and hemolysis rates in an emergency department: analysis of venipuncture versus intravenous catheter collection techniques.
Lowe G, Stike R, Pollack M, Bosley J, O'Brien P, Hake A, Landis G, Billings N, Gordon P, Manzella S, Stover T
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of blood collection by IV catheter versus by venipuncture and blood collection site on the rates of hemolysis. Nurses collected 70 specimens using one randomally assigned method and then collected 70 specimens using the other method. All collections via IV catheter were through a newly placed line. A total of 853 specimens (355 venipuncture and 498 IV catheter) were analyzed for hemolysis by blinded laboratory technicians.
Summary of Findings
A significantly lower rate of hemolysis was found for specimens collected by venipuncture (0.3%) versus those collected via IV catheter (5.6%, p<0.001). Hemolysis rates were not significantly different between IV catheter collection sites. The single hemolyzed specimen was obtained by venipuncture from an anticubital site. The authors also state that catheter size had no significant impact on hemolysis rates.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
MorphologyMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw Anticubital veinForearmHandMore than one siteUnspecifiedWristBiospecimen Acquisition Cannulation Multiple catheter sizesBiospecimen Acquisition Method of fluid acquisition IV catheterVenipuncture