Potassium but not lactate dehydrogenase elevation due to in vitro hemolysis is higher in capillary than in venous blood samples.

Oostendorp M, van Solinge WW, Kemperman H

Publication: Arch Pathol Lab Med (2012) • Vol 136 • Page 1262-5PMID: 23020733View on PubMed

Purpose

The purpose of this paper was to determine the effects of patient age, capillary versus venous blood collection, and hemolytic index on potassium and lactate dehydrogenase levels and the effect of capillary versus venous blood collection on the hemolytic index.

Conclusion

Hemolysis occurred in 63% of capillary specimens and 19% of venous specimens. Potassium levels increased as the hemolytic index increased for both capillary and venous specimens, but the increases were greater among capillary specimens (from children). Lactate dehydrogenase levels also increased in both capillary and venous specimens as the hemolytic index increased, but the rates of increase were not significantly different between capillary and venous specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of patient age, capillary versus venous blood collection, and hemolytic index on potassium and lactate dehydrogenase levels and the effect of capillary versus venous blood collection on the hemolytic index. Specimens from patients younger than 15 years old were included as capillary specimens and those from patients 18 years and older were included as venous specimens. Specimens collected in the emergency department or the intensive care unit were excluded due to the potential that they were collected via intravenous catheter.

Summary of Findings

Hemolysis occurred in 63% of capillary specimens and 19% of venous specimens. Potassium levels increased as the hemolytic index increased for both capillary and venous specimens, but the increases were greater among capillary specimens (from children). Lactate dehydrogenase levels also increased in capillary and venous specimens as the hemolytic index increased, but the rates of increase were not significantly different between capillary and venous specimens.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    ProteinSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    <15 years
    >17 years
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen Aliquots and ComponentsHemolysis
    Absent
    Present