Delay in the measurement of eosin-5-maleimide (EMA) binding does not affect the test result for the diagnosis of hereditary spherocytosis.
Ciepiela O, Górska E, Stelmaszczyk-Emmel A, Popko K, Szmydki-Baran A, Adamowicz-Salach A, Demkow U, Kotula I
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of delayed analysis of EMA stained peripheral blood cells in FBS on the on the results of the flow cytometric test for HS in patients with Microcytic anemia. EDTA anticoagulated peripheral blood from 5 HS pediatric patients and 30 pediatric patients with non-HS Microcytic anemia was stained immediately after collection and stored in the dark in FBS before flow cytometric analysis.
Summary of Findings
Storing stained peripheral blood cells in FBS at 4 degrees C in the dark for 24 h instead of 0 or 1 h had no effect on the results of the EMA binding test for HS.
Biospecimens
FluidBloodCellBloodPreservation Types
Other PreservativeDiagnoses
Other diagnosesPlatforms
Cell count/volumeFlow cytometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Microcytic anemiaStorage Storage duration 0 h1 h24 h