The effect of venous occlusion on the level of serum cholesterol.

KOERSELMAN HB, LEWIS B, PILKINGTON TR

Publication: J Atheroscler Res (1961) • Vol 1 • Page 85-8PMID: 13757507View on PubMed

Purpose

The purpose of this paper was to determine the effects of venous occlusion on the measurement of cholesterol and sodium in serum as well as plasma volume.

Conclusion

Serum cholesterol levels increased while plasma volume decreased when venous occlusion was used during specimen collection. Serum sodium levels showed a small increase when venous occlusion was used during collection.

Studies (1)

Purpose

The purpose of this study was to determine the effects of venous occlusion on the measurement of cholesterol and sodium in serum as well as plasma volume. Venous occlusion was carried out at a pressure of 80 mm mercury (Hg) for 5 min or 1.5-2 min from one arm while blood was collected from the opposite arm using the same sized needle with no venous occlusion. A No. 1 needle was used during venous occlusion for 5 min while a No. 2 needle was used during the collection with venous occlusion for 1.5-2 min.

Summary of Findings

Cholesterol levels were an average of 14.8% higher in specimens collected using No. 1 needles after 5 minutes of venous occlusion than with no venous occlusion. Cholesterol levels were an average of 5.3% higher in specimens collected using No. 2 needles during 1.5-2 min of venous occlusion than with no venous occlusion. Both of these increases in cholesterol were higher than the standard error of the laboratory for blind duplicates. The plasma volume was an average of 14.4% lower after the 5 min venous occlusion compared to the specimens drawn without venous occlusion. Serum sodium rose by less than 3% after venous occlusion.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
    Cell count/volumeHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Tourniquet times compared
    Biospecimen AcquisitionNeedle gauge
    No. 1
    No. 2