The effect of sample handling on cross sectional HIV incidence testing results.

Laeyendecker O, Latimore A, Eshleman SH, Summerton J, Oliver AE, Gamiel J, Dobbs T, Mei J, Murphy G, Parry JV, Owen SM, Quinn TC

Publication: PLoS One (2011) • Vol 6 • Page e25899PMID: 22046249View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage duration and temperature and freeze-thaw cycling of serum on results of 3 different assays that measure human immunodeficiency virus (HIV) response.

Conclusion

Measures of HIV response in serum were unaffected by up to 15 days of storage at 4 or 25 degrees C, but during storage at 37 degrees C, HIV response declined after 3 days using the BED capture enzyme immunoassay and Vironostika less sensitive assay, but the decline was insignificant using the Genetic Systems HIV-1/HIV-2 Plus O avidity assay. Up to 15 freeze-thaw cycles did not impact measures of HIV response, regardless of assay type.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration and temperature and freeze-thaw cycling of serum on 3 different HIV response assays. Serum from 31 HIV positive individuals was stored (and likely shipped) frozen for an unspecified time, thawed, aliquoted and subjected to experimental storage conditions before being returned to -80 degrees C.

Summary of Findings

Measures of HIV response in serum were unaffected by up to 15 days of storage at 4 or 25 degrees C, but during storage at 37 degrees C, HIV response declined after 3 days using the BED capture enzyme immunoassay (p<0.05) and Vironostika less sensitive assay (p<0.01), but the decline was insignificant using the Genetic Systems HIV-1/HIV-2 Plus O avidity assay. Up to 15 freeze-thaw cycles did not impact measures of HIV response, regardless of assay type.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    AIDS/HIV-related
  • Platforms

    GlycoproteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageFreeze/thaw cycling
    1 cycle
    15 cycles
    3 cycles
    7 cycles
    StorageStorage duration
    1 day
    15 days
    3 days
    7 days
    StorageStorage temperature
    -80 degrees C
    25 degrees C
    37 degrees C
    4 degrees C
    Immunoassay SpecificTechnology platform
    BED capture enzyme immunoassay
    Genetic Systems HIV-1/HIV-2 Plus O avidity assay
    Vironostika less sensitive assay