Thawed solvent/detergent-treated plasma: too precious to be wasted after 6 hours?
Keller MK, Pruss A, Sander M, Spies C, Schoenfeld H, Schuster M, Meinck K, Wernecke KD, von Heymann C
Purpose
The purpose of this paper was to determine the effects of refrigerated storage on clotting factors and inhibitors in thawed solvent/detergent (S/D) treated plasma.
Conclusion
Compared to levels measured immediately after thawing, S/D plasma stored for 6 days had significantly lower factor (F)II, FV, FVII, FVIII, FIX, FX, free protein S, antithrombin, fibrinogen, FXIII, and plasmin inhibitor levels and higher protein C levels. However, the only clinically relevant changes were decreases in FVII and FVIII that were observed when S/D plasma was stored for more than 24 h.
Studies (1)
Purpose
The purpose of this study was to determine the effects of refrigerated storage on clotting factors and inhibitors in thawed S/D treated plasma. Octaplas brand solvent/detergent treated pooled plasma from frequent donors was stored at -30 degrees C. S/D plasma was thawed on a PlasmaTherm III, stored at 4 degrees C and shaken gently before sampling.
Summary of Findings
Compared to levels measured immediately after thawing, S/D plasma stored for 6 days had significantly lower FII (p<0.0001), FV (p<0.0001), FVII (p<0.0001), FVIII (p<0.0001), FIX (p<0.0001), FX (p<0.0001), free protein S (p<0.0001), antithrombin (p<0.0001), fibrinogen (p=0.0204), FXIII (p=0.0019), and plasmin inhibitor levels (p=0.0299) and higher protein C levels (p=0.0371). During the first 6 h of refrigerated storage, levels of FII levels increased (p=0.0028) and levels of FVIII and FIX decreased (p=0.01 and p<0.0001, respectively). Between 6 and 24 h of refrigerated storage significant declines in FII (p<0.0001), FV (p<0.0001), FVII (p<0.0001), FVIII (p<0.0029), FX (p=0.0229), FXIII (p<0.001), and free protein S levels (p<0.001) and increases in plasmin inhibitor levels (p=0.0192) were observed. Between 24 h and 6 days of refrigerated storage, levels of FII, FVII, and plasmin inhibitor decreased (p=0.004, p<0.0001, and p=0.0019, respectively), levels of FX increased (p=0.0015), and a significant change in FV levels was reported (p=0.003), but median levels and range were unchanged. FXI, FXII and VWF-Ag levels in thawed S/D treated plasma were not affected by up to 6 days of refrigerated storage. Only the changes in FVII and FVIII levels when S/D plasma was stored for more than 24 h were considered clinically relevant.
Biospecimens
FluidPlasmaPreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinClinical chemistry/auto analyzerProteinHematology/ auto analyzerGlycoproteinClinical chemistry/auto analyzerGlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 h24 h48 h6 days6 h