Skip to main content

Comparison of ethanol and other drugs of abuse concentrations in whole blood stored in venoject glass and plastic and venosafe plastic evacuated tubes.

Karinen R, Oiestad EL, Andresen W, Wethe G, Smith-Kielland A, Christophersen A

Publication: J Anal Toxicol (2010) • Vol 34 • Page 420-8PMID: 20822681View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage container, storage temperature and freeze-thaw cycling on measurement of alcohols and drugs of abuse in spiked blood specimens.

Conclusion

While levels of many of the alcohols and drugs tested changed during storage of whole blood, most changes were less than 20% and differences between tube materials and anticoagulants were less than 30%.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage container, storage temperature and freeze-thaw cycling on measurement of spiked alcohols and drugs of abuse. The 5 mL glass vacutainer and 4 mL plastic venosafe tubes contained sodium fluoride/heparin and the 4 mL plastic vacutainer contained sodium fluoride potassium oxalate. Specimens stored at -20 degrees C were subjected to 3 freeze-thaw cycles prior to analysis.

Summary of Findings

Ethanol, methanol, isopropanol and acetone levels changed by less than 6% after 1 week of storage, regardless of storage container or temperature. Levels of the 11 benzodiazepines and related drugs generally changed by less than 20% after specimens were stored for 1 week at room temperature or -20 degrees C, regardless of storage container, but zopiclone levels declined by 67-91% after storage at room temperature and increased by as much as 24% when low concentration specimens were stored at -20 degrees C in Vacutainer tubes (plastic or glass). Levels of the 9 opiates and opiods generally changed by less than 20% after storage at -20 degrees C, but tramado levels decline by as much as 23.5% after storage in glass vacutainers at -20 degrees C. Storage of specimens containing opiates or opiods at room temperature led to changes of up to 41% depending on compound, concentration and tube type. Levels of Amphetamine and methylenedioxymethamphetamine (MDMA) changed by less than 20%, regardless of tube type and temperature, but metamphetamine, cocaine, and methylphenidat levels changed by as much as 27.9%, 61.3%, and 70.3%, respectively, when stored at room temperature, and methylphenidat changed by as much as 24.2% after storage at -20 degrees C. Levels of Gamma hydroxybutyrate (GHB), gabapentin, atomoxetine and pregabalin changed by less than 20% after storage at room temperature or -20 degrees C, regardless of storage container, but levels of tetrahydrocannabinol (THC), ketamine, levomepromazine, mirtazapine, venlafaxine, and citalopram changed by more than 20%, depending on storage temperature and container. Differences in levels between tubes types after 1 week storage at room temperature or -20 degrees C were less than 30%, which the authors state is an acceptable deviation for forensic analysis.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)Frozen
  • Diagnoses

    Not specified
  • Platforms

    Small moleculeGC- flame ionization
    Small moleculeLC-MS or LC-MS/MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Sodium fluoride/heparin
    Sodium fluoride/potassium oxalate
    Biospecimen Aliquots and ComponentsBiospecimen components
    Blood spiked with one of 4 alcohols or 35 drugs of abuse
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageFreeze/thaw cycling
    0 cycles
    3 cycles
    StorageStorage temperature
    -20 degrees C
    Room temperature
    StorageType of storage container
    Vacutainer glass tube
    Vacutainer plastic tube
    Venosafe plastic tube