Blood sample collection from a peripheral catheter system compared with phlebotomy.
Seemann S, Reinhardt A
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collecting blood using an existing saline lock device as opposed to through venipuncture on levels of sodium, chloride, and potassium, and hemolysis rates in serum. Specimens were obtained through the saline lock device within 10-15 minutes of those obtained through venipuncture. The authors specify that a tourniquet was used during the collection of specimens using the saline lock device.
Summary of Findings
There were no significant differences between the levels of sodium, chloride, or potassium in serum from specimens obtained through a saline lock device and those obtained through venipuncture. Out of 19 attempts to collect specimens through the saline lock device, two were unsuccessful, and 4 of the 17 successful collections were hemolyzed. None of the venipuncture specimens was hemolyzed. The authors note that while saline lock devices in this study had all been in place for 24-72 hours, the 4 specimens that were hemolyzed were drawn from saline lock devices that had been in place for an average of 24-48 hours.
Biospecimens
FluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerMorphologyMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Saline lock deviceVenipuncture