Collecting factors related to the haemolysis of blood specimens.
Fang L, Fang SH, Chung YH, Chien ST
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of patient characteristics and blood collection variables on the rates of hemolysis among 274 blood specimens.
Summary of Findings
Univariate analysis revealed hemolysis was significantly more likely to occur in specimens collected from a non-anticubital venipuncture as opposed to an anticubital venipuncture, collection by an IV catheter rather than a steel needle, or collection into a tube through the needle or catheter rather than removal of the needle and collection of blood into the tube through the syringe. Further, univariate analysis also determined hemolysis was significantly more likely to occur after inverting the tube 8-12 times after collection or unnecessarily shaking it as opposed to inverting it less than 8 or more than 12 times, shaking it horizontally, or not shaking it at all and when specimens were collected into non-serum tubes versus serum tubes, but the authors do not elaborate on the types or contents of the tubes used in this study. Interestingly, significantly higher rates of hemolysis were observed among specimens delivered to the laboratory by ward assistants than by laboratory staff. Of these 6 blood collection variables, only three were significantly associated with hemolysis after multivariate analysis, including obtaining a specimen from a non-anticubital venipuncture (p=0.001), collecting blood into the tube through the needle as opposed to the syringe after removing the needle (p=0.002), and hand-delivery of specimens by ward assistants rather than laboratory staff (p<0.01). Patient age and gender had no effects on hemolysis. The authors report that tourniquet time also had no effects on hemolysis, although specific times used in the study were not included. The authors report that sample size was too small for each of the catheter and steel needle gauges so the effects on hemolysis rates were unable to be determined.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
MorphologyMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Patient age 19-96 years oldPreaquisition Patient gender FemaleMaleBiospecimen Acquisition Anatomical location of blood draw Anticubital veinNon-anticubital veinBiospecimen Acquisition Cannulation 16 gauge18 gauge20 gauge22 gauge24 gaugeBiospecimen Acquisition Method of fluid acquisition IV catheterNeedleSyringe drawTourniquet times comparedBiospecimen Acquisition Needle gauge 16 gauge18 gauge20 gauge22 gauge24 gaugeBiospecimen Acquisition Type of collection container/solution Non-serum tubeSerum tubeBiospecimen Aliquots and Components Biospecimen mixing Inverted 8-12 timesInverted < 8 timesInverted >12 timesNo mixingShook horizontallyUnnecessarily shakenStorage Specimen transport duration/condition Transported by laboratory staffTransported by ward assistantsStorage Within hospital transportation method Hand-delivered