Skip to main content

Collecting factors related to the haemolysis of blood specimens.

Fang L, Fang SH, Chung YH, Chien ST

Publication: J Clin Nurs (2008) • Vol 17 • Page 2343-51PMID: 18047574View on PubMed

Purpose

The purpose of this paper was to determine the effects of 10 blood collection variables on the rates of hemolysis among 274 blood specimens.

Conclusion

Of the 10 blood collection variables evaluated, only obtaining a specimen from a non-anticubital venipuncture, collecting blood into the tube through the needle as opposed to the syringe after removing the needle, and hand-delivery of specimens by ward assistants rather than laboratory staff were significantly associated with hemolysis after multivariate analysis.

Studies (1)

Purpose

The purpose of this study was to determine the effects of patient characteristics and blood collection variables on the rates of hemolysis among 274 blood specimens.

Summary of Findings

Univariate analysis revealed hemolysis was significantly more likely to occur in specimens collected from a non-anticubital venipuncture as opposed to an anticubital venipuncture, collection by an IV catheter rather than a steel needle, or collection into a tube through the needle or catheter rather than removal of the needle and collection of blood into the tube through the syringe. Further, univariate analysis also determined hemolysis was significantly more likely to occur after inverting the tube 8-12 times after collection or unnecessarily shaking it as opposed to inverting it less than 8 or more than 12 times, shaking it horizontally, or not shaking it at all and when specimens were collected into non-serum tubes versus serum tubes, but the authors do not elaborate on the types or contents of the tubes used in this study. Interestingly, significantly higher rates of hemolysis were observed among specimens delivered to the laboratory by ward assistants than by laboratory staff. Of these 6 blood collection variables, only three were significantly associated with hemolysis after multivariate analysis, including obtaining a specimen from a non-anticubital venipuncture (p=0.001), collecting blood into the tube through the needle as opposed to the syringe after removing the needle (p=0.002), and hand-delivery of specimens by ward assistants rather than laboratory staff (p<0.01). Patient age and gender had no effects on hemolysis. The authors report that tourniquet time also had no effects on hemolysis, although specific times used in the study were not included. The authors report that sample size was too small for each of the catheter and steel needle gauges so the effects on hemolysis rates were unable to be determined.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    MorphologyMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    19-96 years old
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen AcquisitionAnatomical location of blood draw
    Anticubital vein
    Non-anticubital vein
    Biospecimen AcquisitionCannulation
    16 gauge
    18 gauge
    20 gauge
    22 gauge
    24 gauge
    Biospecimen AcquisitionMethod of fluid acquisition
    IV catheter
    Needle
    Syringe draw
    Tourniquet times compared
    Biospecimen AcquisitionNeedle gauge
    16 gauge
    18 gauge
    20 gauge
    22 gauge
    24 gauge
    Biospecimen AcquisitionType of collection container/solution
    Non-serum tube
    Serum tube
    Biospecimen Aliquots and ComponentsBiospecimen mixing
    Inverted 8-12 times
    Inverted < 8 times
    Inverted >12 times
    No mixing
    Shook horizontally
    Unnecessarily shaken
    StorageSpecimen transport duration/condition
    Transported by laboratory staff
    Transported by ward assistants
    StorageWithin hospital transportation method
    Hand-delivered