Incorrect order of draw of blood samples does not cause potassium EDTA sample contamination.
Cornes MR, Sulaiman RA, Whitehead SJ, Othonos N, Ford C, Gama R
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of filling BD Vacutainer SST II gel tubes before or after BD EDTA tubes containing potassium EDTA on EDTA contamination, potassium, calcium, magnesium, zinc, and alkaline phosphatase in serum. Serum was stored at -80 degrees C until analysis.
Summary of Findings
There were no differences in potassium, calcium, magnesium, zinc, or alkaline phosphatase levels in specimens collected in SST II gel tubes before or after collection of a specimen in an EDTA tube. In addition, EDTA contamination was undetectable in all specimens (<0.2 mmol/L).
Biospecimens
FluidSerumFluidBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
Small moleculeClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot sequential collection 1st collection3rd collection