Skip to main content

Incorrect order of draw of blood samples does not cause potassium EDTA sample contamination.

Cornes MR, Sulaiman RA, Whitehead SJ, Othonos N, Ford C, Gama R

Publication: Br J Biomed Sci (2012) • Vol 69 • Page 136-8PMID: 23057163View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube order on EDTA contamination, potassium, calcium, magnesium, zinc, and alkaline phosphatase in serum.

Conclusion

There were no differences in potassium, calcium, magnesium, zinc, or alkaline phosphatase levels in specimens collected in BD Vacutainer serum separator tube (SST) II gel tubes before or after collection of a specimen in a BD EDTA tube containing potassium EDTA. In addition, EDTA contamination was undetectable in all specimens (<0.2 mmol/L).

Studies (1)

Purpose

The purpose of this study was to determine the effects of filling BD Vacutainer SST II gel tubes before or after BD EDTA tubes containing potassium EDTA on EDTA contamination, potassium, calcium, magnesium, zinc, and alkaline phosphatase in serum. Serum was stored at -80 degrees C until analysis.

Summary of Findings

There were no differences in potassium, calcium, magnesium, zinc, or alkaline phosphatase levels in specimens collected in SST II gel tubes before or after collection of a specimen in an EDTA tube. In addition, EDTA contamination was undetectable in all specimens (<0.2 mmol/L).

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    Small moleculeClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    3rd collection