Influence of a 24-hour interruption of agitation on in vitro properties of platelets washed with M-sol during 7-day storage.
Hirayama J, Fujihara M, Akino M, Homma C, Kato T, Ikeda H, Azuma H
Purpose
The purpose of this paper was to determine the effects of a 24 h interruption in agitation of platelets (PLTs) on markers of PLT quality.
Conclusion
Partial pressure carbon dioxide (pCO2), partial pressure oxygen (pO2), mean PLT volume (MPV), P-selectin and lactate were significantly higher, and glucose and pH were significantly lower after storage in a shipping container on the bench than in specimens kept on the agitator, but these differences were no longer observed after day 3. The authors conclude that any effect of a 24 h interruption in agitation is mostly attenuated when specimens are returned to the agitator.
Studies (1)
Purpose
The purpose of this study was to determine the effects of a 24 h interruption in agitation on markers of PLT quality. PLTs were stored for 4-5 days at room temperature on a flatbed agitator before being resuspended in M-Sol (day 0) and returned to a flatbed shaker. On day 1, half of the bags were placed in a shipping container on a laboratory bench without agitation and stored there for 24 h, after which time they were returned to the flat bed agitator (Day 2).
Summary of Findings
While pH was significantly lower in PLTs placed for 24 h in a storage box on the bench instead of being stored with continual agitation after 2 and 3 days (p<0.01), the decrease was not maintained throughout the storage period, and the pH remained within an acceptable range at all timepoints. pCO2, pO2, MPV, P-selectin and lactate were significantly higher and glucose was significantly lower immediately after specimens were stored in the shipping container on the bench for 24 h than in specimens kept on the agitator (p<0.01, all), but this difference was no longer observed by day 4, 3, 3, 4, 4, and 4 for each analyte, respectively. The percentage of discoid PLTs (%disc), annexin V, aggregation, and heat shock response (HSR) were not significantly different in specimens stored for 24 h in a shipping container without agitation than in those stored with continual agitation. The authors conclude that any effect of a 24 h interruption in agitation is mostly attenuated when specimens are returned to the agitator.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Small moleculeClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerCell count/volumeHematology/ auto analyzerCell count/volumeFlow cytometryProteinClinical chemistry/auto analyzerMorphologyHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage conditions With a 24 h interruption in agitationWith continual agitationStorage Time at room temperature 1 day2 days3 days4 days7 days