Skip to main content

Hemolysis of red blood cells during processing and storage.

Gkoumassi E, Dijkstra-Tiekstra MJ, Hoentjen D, de Wildt-Eggen J

Publication: Transfusion (2012) • Vol 52 • Page 489-92PMID: 21827508View on PubMed

Purpose

The purpose of this paper was to determine the relationship between a greater than 6 min blood separation time using a Compomat G4 and hemoglobin (Hb), hematocrit (Hct), platelet (PLT) counts and hemolysis, as well as to determine the effects of 5 weeks of storage at 4 degrees C on the hemolysis rate in red blood cells (RBCs) stored in saline-adenine-glucose-mannitol (SAGM).

Conclusion

Hb, Hct, and PLT count were not significantly different when Compomat G4 blood separation took more or less than 6 minutes, but a significantly higher mean hemolysis rate was observed among the specimens that required more than 6 minutes for automated separation compared to those that required less than 6 minutes. 4 of 172 specimens with a >6 min separation time were classified as hemolytic, while 0 of 172 specimens with a <6 min separation time were classified as hemolytic. After storage of RBCs in SAGM for 5 weeks, hemolysis rates increased by an average of 0.24%, with large increases observed in all specimens, regardless of separation time.

Studies (1)

Purpose

The purpose of this study was to determine the relationship between a greater than 6 min blood separation time using a Compomat G4 and Hb, Hct, PLT counts and hemolysis, as well as to determine the effects of 5 weeks of storage at 4 degrees C on the hemolysis rate in RBCs in SAGM. Donor blood in citrate phosphate dextrose (CPD) was stored at room temperature for 4-24 h, centrifuged and separated automatically using a Compomat G4, which gave an audible signal when separation of blood components took more than 6 min. White blood cells were removed by filtration and RBCs were stored in SAGM and refrigerated in diethylhexyl phthalate bags.

Summary of Findings

Hb, Hct, and PLT counts were not significantly different when Compomat G4 blood separation took more or less than 6 minutes, but a significantly higher mean hemolysis rate was observed among the specimens that required more than 6 minutes for automated separation (0.058%) compared to those that required less than 6 minutes (0.033%, p<0.05). 4 of 172 specimens with a >6 min separation time were classified as hemolytic, while 0 of 172 specimens with a <6 min separation time were classified as hemolytic. After storage of RBCs in SAGM for 5 weeks, hemolysis rates increased by an average of 0.24%, with large increases observed in all specimens, regardless of separation time.

  • Biospecimens

    FluidBlood
    CellRed Blood Cells
  • Preservation Types

    Other Preservative
  • Diagnoses

    Not specified
  • Platforms

    ProteinHematology/ auto analyzer
    Cell count/volumeHematology/ auto analyzer
    Cell count/volumeSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood processing method
    Blood seperation taking <6 min
    Blood seperation taking >6 min
    StorageStorage duration
    0 days
    5 weeks