Skip to main content

Use of separate venipunctures for IV access and laboratory studies decreases hemolysis rates.

Straszewski SM, Sanchez L, McGillicuddy D, Boyd K, Dufresne J, Joyce N, Wolfe R, Lee AW, Fisher J, Mottley JL

Publication: Intern Emerg Med (2011) • Vol 6 • Page 357-9PMID: 21468698View on PubMed

Purpose

The purpose of this paper was to determine the effects of a policy mandating the use of a separate venipuncture for laboratory analysis on hemolysis rates.

Conclusion

Mandatory collection of blood specimens for laboratory analysis with a separate venipuncture using a butterfly needle rather than either using a butterfly needle or collecting blood through an IV catheter resulted in significant decreases in specimen hemolysis rates (23.0% to 6.6%).

Studies (1)

Purpose

The purpose of this study was to determine the effects of a policy mandating the use of a separate venipuncture for collection of specimens intended for laboratory analysis versus collection of specimens either by venipuncture with a butterfly needle or through an existing IV catheter on hemolysis rates among emergency department patients.

Summary of Findings

Mandatory collection of blood specimens for laboratory analysis with a separate butterfly needle venipuncture rather than either using a butterfly needle or collecting blood through an IV catheter resulted in significant decreases in specimen hemolysis rates (23.0% to 6.6%). Importantly, the percentage of hemolyzed specimens requiring a redraw due to critical potassium levels also decreased once the separate venipuncture policy was put in place.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeMacroscopic observation
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Butterfly device
    IV catheter