Flow cytometric lymphocyte subset analysis using material from frozen whole blood.
Alam I, Goldeck D, Larbi A, Pawelec G
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of analysis of whole blood rather than PBMC and the duration of frozen storage on results of flow cytometric analysis of lymphocytes.
Summary of Findings
The authors report that using whole blood instead of PBMC resulted in the loss of more than 50% of the CD3+ cells. However, the percentage of CD4+ and CD8+ T-cell populations were not significantly different between frozen whole blood and PBMC. Further, CD4 and CD8 T-cell subpopulations, sorted based on CD27, CD28, CCR7, and CD57 status, were not affected by the use of whole blood rather than PBMC. The CD28+ subpopulation of CD3+ T-cells was reduced in whole blood stored frozen for 120 days compared to PBMC stored frozen for 10 days (p=0.0377). Storing PBMC or whole blood for 120 days instead of 10 days did not impact cell counts. The authors report whole blood tended to form clumps of dead cells during frozen storage, but washing specimens in phosphate buffered saline with EDTA prevented the clumps from interfering with assay. Further, the authors report lysis of the red blood cells decreased the time required for flow cytometry without affecting cell counts.
Biospecimens
FluidBloodCellBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
Cell count/volumeFlow cytometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products Peripheral blood mononuclear cellsWhole bloodStorage Storage duration 10 days120 days