Evaluation of sample hemolysis in blood collected by S-Monovette using vacuum or aspiration mode.

Lippi G, Avanzini P, Musa R, Sandei F, Aloe R, Cervellin G

Publication: Biochem Med (Zagreb) (2013) • Vol 23 • Page 64-9PMID: 23457766View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood collection tube type and collecting blood by vacuum versus forced aspiration on cell-free hemoglobin, potassium, and lactate dehydrogenase (LD) levels in serum.

Conclusion

None of the specimens collected had clinically significant hemolysis, and there were no significant differences in potassium or LD levels between specimens collected by vacuum in S-Monovette tubes or in Vacutainers. However, potassium and LD levels were significantly lower in specimens collected in S-Monovette tubes by aspiration than in specimens collected in S-Monovette or Vacutainer tubes by vacuum. Importantly, all of these significant differences were less than the allowable total error for each analyte.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood collection tube type and collecting blood by vacuum versus forced aspiration on cell-free hemoglobin, potassium, and LD levels in serum.

Summary of Findings

None of the specimens collected had clinically significant hemolysis, and there were no significant differences in potassium or LD levels between specimens collected by vacuum in S-Monovette tubes or in Vacutainers. However, potassium and LD levels were significantly lower in specimens collected in S-Monovette tubes by aspiration (syringe-style draw) than in specimens collected in S-Monovette or Vacutainer tubes by vacuum. Importantly, all of these significant differences, ranging on average from 2.1-2.7%, were less than the allowable total error for each analyte.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeSpectrophotometry
    ProteinClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Syringe draw
    Vacuum tube
    Biospecimen AcquisitionType of collection container/solution
    S-Monovette serum tube (no gel separator)
    Vacutainer serum tube (no gel separator)