Reducing blood sample hemolysis at a tertiary hospital emergency department.
Ong ME, Chan YH, Lim CS
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of blood collection technique and an educational intervention for hospital staff on the rates of hemolysis among blood specimens. Personnel performing each blood collection filled out a standard questionnaire which included questions about perceived rate of blood flow (fast, moderate, or slow) and perceived difficulty of venipuncture/cannulation (easy, moderate, or hard).
Summary of Findings
The rates of hemolysis were either not associated or had poor associations with sample volume, needle gauge, perceived rate of blood flow, difficulty of cannulation/venipuncture, the interval between collection and processing, or what type of hospital personnel was performing the collection. However, significantly higher rates of hemolysis were observed when an IV cannula was used (24.4%) rather than venipuncture (6.8%), and when a Vacutainer was used (35.8%) instead of a syringe (11.0%) for collection. The overall rates of hemolysis were significantly lower after the educational intervention (4.9%) compared to before (19.8%), and the use of an IV cannula as opposed to venipuncture and Vacutainers as opposed to syringes for collection decreased after intervention.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw ArteryVeinBiospecimen Acquisition Method of fluid acquisition Blood flow rates comparedDifficult blood drawIV catheterNot a difficult blood drawStaff trained/experienced in phlebotomyStaff untrained/inexperienced in phlebotomySyringe drawVacuum tubeVenipunctureBiospecimen Acquisition Needle gauge 21 gauge or lower>21 gaugeBiospecimen Aliquots and Components Aliquot size/volume A range of blood collection volumesStorage Time at room temperature A range of collection to processing intervals