Interchangeability of venous and capillary HbA1c results is affected by oxidative stress.

Godefroid MJ, De Buyzere ML, Delanghe JR

Publication: Clin Chem Lab Med (2012) • Vol 51 • Page e9PMID: 23096018View on PubMed

Purpose

The purpose of this paper was to determine the effects of capillary versus venous sampling and creatine kinase (CK) levels on hemoglobin A1c (HbA1c) levels in specimens from healthy individuals and intensive care patients.

Conclusion

HbA1c levels were not significantly different between venous and capillary blood specimens drawn from healthy individuals. However, capillary specimens from intensive care patients had significantly lower levels of HbA1c than simultaneously collected venous specimens. It was determined that this significant difference occurred specifically in specimens with low levels of CK (high oxidative stress). Significantly higher levels of HbA1c were measured in the high-density fraction of red blood cells from venous specimens, as opposed to the low-density fraction.

Studies (1)

Purpose

The purpose of this study was to determine the effects of capillary versus venous sampling and CK levels, as an oxidative stress marker, on HbA1c levels in specimens from healthy individuals and intensive care patients. Venous specimens were collected into Terumo K2EDTA Venosafe tubes while capillary specimens were collected in heparinized Minicaps capillary tubes.

Summary of Findings

HbA1c levels were not significantly different between venous and capillary blood specimens drawn from healthy individuals. However, capillary specimens from intensive care patients had significantly lower levels of HbA1c than simultaneously collected venous specimens (p=0.01). It was determined that this significant difference occurred specifically in specimens with low levels of CK (high oxidative stress) (p=0.04). Significantly higher levels of HbA1c were measured in the high-density fraction of red blood cells from venous specimens as opposed to the low-density fraction (p=0.004).

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Other diagnoses
  • Platforms

    ProteinClinical chemistry/auto analyzer
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    High CK
    Low CK
    Moderate CK
    PreaquisitionDiagnosis/ patient condition
    Intensive care patient
    Normal
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen Aliquots and ComponentsBiospecimen components
    High-density fraction of red blood cells
    Low-density fraction of red blood cells