The purpose of this paper was to determine the effects of collection tube type and storing uncentrifuged whole blood, plasma or serum at 4 or 25 degrees C on the levels of 81 clinical chemistry and hematological analytes in serum and plasma.
Stability study of 81 analytes in human whole blood, in serum and in plasma.
Oddoze C, Lombard E, Portugal H
Purpose
Conclusion
Generally, analytes were more stable in uncentrifuged blood, plasma or serum stored in plain glass tubes than in lithium heparin tubes or SST. Furthermore, overall, analytes were more stable when whole blood, serum or plasma was stored at 4 degrees C than 25 degrees C. The analytes demonstrating exceptions to these trends were potassium, which increased more rapidly with storage of serum or whole blood in glass tubes at 25 degrees C than at 4 degrees C, and c-telopeptide, osteolcalcin, insulin, and parathyroid hormone (PTH), which were more stable in uncentrifuged blood or plasma stored in K3EDTA tubes than in plain glass tubes. 20 of the 81 analytes examined were affected by storage of uncentrifuged whole blood, plasma or serum, including follicle stimulating hormone (FSH), estradiol, prolactin, folate, insulin, c-peptide, PTH, osteocalcin, c-telopeptide, adrenocorticotropic hormone (ACTH), potassium, lactate, lactate dehydrogenase (LDH), magnesium, bicarbonate, glucose, inorganic phosphorous, mean corpuscular volume (MCV), activated partial thromboplastin time (APTT), and mean corpuscular hemoglobin (MCH).
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection tube type and storing uncentrifuged whole blood, plasma or serum at 4 or 25 degrees C on levels of 81 clinical chemistry and hematological analytes in serum and plasma from healthy volunteers. The effects of storing whole blood prior to centrifugation in SST tubes were not investigated. Lithium heparin was used for biochemical analytes, sodium fluoride was used for measurement of glucose and lactate, K3EDTA was used for hormonal and hematological analysis, and citrate, theophylline, adenosine, and dipyridamole cocktail (CTAD) tubes were used for coagulation analysis.
Summary of Findings
Generally, analytes were more stable in uncentrifuged blood, plasma or serum stored in plain glass tubes than lithium heparin tubes or SST. Furthermore, overall, analytes were more stable when whole blood, serum or plasma was stored at 4 degrees C than 25 degrees C. The analytes demonstrating exceptions to these trends were potassium, which increased more rapidly with storage of serum or whole blood in glass tubes at 25 degrees C than at 4 degrees C, and c-telopeptide, osteolcalcin, insulin, and PTH, which were more stable in uncentrifuged blood or plasma stored in K3EDTA tubes than in plain glass tubes. 20 of the 81 analytes examined were affected by storage of uncentrifuged whole blood, plasma or serum, including FSH, estradiol, prolactin, folate, insulin, c-peptide, PTH, osteocalcin, c-telopeptide, ACTH, potassium, lactate, LDH, magnesium, bicarbonate, glucose, inorganic phosphorous, MCV, APTT, and MCH. The direction and degree of analyte changes due to storage were tube type, storage temperature, and biospecimen type (whole blood, serum, plasma) specific.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
CarbohydrateClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerGlycoproteinClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerLipoproteinClinical chemistry/auto analyzerPeptideClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerGlycoproteinHematology/ auto analyzerCell count/volumeHematology/ auto analyzerProteinHematology/ auto analyzerMorphologyHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Plain glass tubePlasma tubeSSTBiospecimen Aliquots and Components Blood and blood products PlasmaSerumWhole bloodBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage duration 0 h2 h24 h4 h6 h72 hStorage Storage temperature 25 degrees C4 degrees C