Skip to main content

Stability study of 81 analytes in human whole blood, in serum and in plasma.

Oddoze C, Lombard E, Portugal H

Publication: Clin Biochem (2012) • Vol 45 • Page 464-9PMID: 22285385View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube type and storing uncentrifuged whole blood, plasma or serum at 4 or 25 degrees C on the levels of 81 clinical chemistry and hematological analytes in serum and plasma.

Conclusion

Generally, analytes were more stable in uncentrifuged blood, plasma or serum stored in plain glass tubes than in lithium heparin tubes or SST. Furthermore, overall, analytes were more stable when whole blood, serum or plasma was stored at 4 degrees C than 25 degrees C. The analytes demonstrating exceptions to these trends were potassium, which increased more rapidly with storage of serum or whole blood in glass tubes at 25 degrees C than at 4 degrees C, and c-telopeptide, osteolcalcin, insulin, and parathyroid hormone (PTH), which were more stable in uncentrifuged blood or plasma stored in K3EDTA tubes than in plain glass tubes. 20 of the 81 analytes examined were affected by storage of uncentrifuged whole blood, plasma or serum, including follicle stimulating hormone (FSH), estradiol, prolactin, folate, insulin, c-peptide, PTH, osteocalcin, c-telopeptide, adrenocorticotropic hormone (ACTH), potassium, lactate, lactate dehydrogenase (LDH), magnesium, bicarbonate, glucose, inorganic phosphorous, mean corpuscular volume (MCV), activated partial thromboplastin time (APTT), and mean corpuscular hemoglobin (MCH).

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube type and storing uncentrifuged whole blood, plasma or serum at 4 or 25 degrees C on levels of 81 clinical chemistry and hematological analytes in serum and plasma from healthy volunteers. The effects of storing whole blood prior to centrifugation in SST tubes were not investigated. Lithium heparin was used for biochemical analytes, sodium fluoride was used for measurement of glucose and lactate, K3EDTA was used for hormonal and hematological analysis, and citrate, theophylline, adenosine, and dipyridamole cocktail (CTAD) tubes were used for coagulation analysis.

Summary of Findings

Generally, analytes were more stable in uncentrifuged blood, plasma or serum stored in plain glass tubes than lithium heparin tubes or SST. Furthermore, overall, analytes were more stable when whole blood, serum or plasma was stored at 4 degrees C than 25 degrees C. The analytes demonstrating exceptions to these trends were potassium, which increased more rapidly with storage of serum or whole blood in glass tubes at 25 degrees C than at 4 degrees C, and c-telopeptide, osteolcalcin, insulin, and PTH, which were more stable in uncentrifuged blood or plasma stored in K3EDTA tubes than in plain glass tubes. 20 of the 81 analytes examined were affected by storage of uncentrifuged whole blood, plasma or serum, including FSH, estradiol, prolactin, folate, insulin, c-peptide, PTH, osteocalcin, c-telopeptide, ACTH, potassium, lactate, LDH, magnesium, bicarbonate, glucose, inorganic phosphorous, MCV, APTT, and MCH. The direction and degree of analyte changes due to storage were tube type, storage temperature, and biospecimen type (whole blood, serum, plasma) specific.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    GlycoproteinClinical chemistry/auto analyzer
    LipidClinical chemistry/auto analyzer
    LipoproteinClinical chemistry/auto analyzer
    PeptideClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
    GlycoproteinHematology/ auto analyzer
    Cell count/volumeHematology/ auto analyzer
    ProteinHematology/ auto analyzer
    MorphologyHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Plain glass tube
    Plasma tube
    SST
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    0 h
    2 h
    24 h
    4 h
    6 h
    72 h
    StorageStorage temperature
    25 degrees C
    4 degrees C