Skip to main content

Prevention of hemolysis in blood samples collected from intravenous catheters.

Lippi G, Avanzini P, Cervellin G

Publication: Clin Biochem (2013) • Vol 46(7-8) • Page 561-4PMID: 23391635View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood collection method (vacuum tube versus manual aspiration) and tube type on cell-free hemoglobin, lactate dehydrogenase (LDH), and potassium levels in serum specimens drawn through an intravenous (IV) catheter.

Conclusion

There were no significant differences in cell-free hemoglobin, LDH, or potassium levels between specimens collected by vacuum into BD serum separator tubes (SST) II plus and those collected in S-Monovette serum tubes. However, specimens collected via vacuum into either tube type had significantly higher rates of hemolysis, and cell-free hemoglobin, LDH, and potassium levels than specimens collected into S-Monovette serum tubes by manual aspiration.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood collection method (vacuum tube versus manual aspiration) and tube type on cell-free hemoglobin, LDH, and potassium levels in serum specimens drawn through an IV catheter from emergency room patients with a variety of diagnoses.

Summary of Findings

There were no significant differences in cell-free hemoglobin, LDH, or potassium levels between specimens collected by vacuum into BD SST II Plus and those collected in S-Monovette serum tubes. However, specimens collected via vacuum into either tube type had significantly higher rates of hemolysis, and cell-free hemoglobin, LDH, and potassium levels than specimens collected into S-Monovette serum tubes by manual aspiration.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Epilepsy
    Hypertension
    Diabetes Type 2
    Other diagnoses
  • Platforms

    Cell count/volumeSpectrophotometry
    ProteinSpectrophotometry
    ProteinClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Syringe draw
    Vacuum tube
    Biospecimen AcquisitionType of collection container/solution
    BD SST II Plus
    S-Monovette serum tube