Effects of hemolysis and storage condition on neuron-specific enolase (NSE) in cerebrospinal fluid and serum: implications in clinical practice.
Ramont L, Thoannes H, Volondat A, Chastang F, Millet MC, Maquart FX
Purpose
The purpose of this paper was to determine the effects of frozen storage temperature and duration and hemolysis on the levels of neuron specific enolase (NSE) in serum and cerebrospinal fluid (CSF).
Conclusion
NSE levels were significantly lower than levels measured in fresh specimens when CSF was stored at -20 degrees C for 1 month or at -80 degrees C for 8 months prior to analysis, but NSE levels were unaffected by storage of serum at -80 degrees C for up to 9 months. NSE levels in serum and CSF were very strongly correlated with the hemolysis index.
Studies (2)
Purpose
The purpose of this study was to determine the effects of frozen storage and hemolysis on the measurement of NSE in CSF from patients suspected of having neurodegenerative disease. Aliquots of CSF were placed in polyethelene tubes for storage and recentrifuged before analysis. Hemolysate was prepared by lysing cells with toluene and water and vortexing.
Summary of Findings
NSE levels were 27.6% lower than initial levels when CSF was stored at -20 degrees C for 1 month prior to analysis (p<0.0001). A nonsignificant 5.3% decline in CSF NSE levels was found after 6 months of storage at -80 degrees C compared to levels in fresh specimens. NSE in CSF declined by 19.5% after 8 months of storage at -80 degrees C compared to levels in fresh specimens (p<0.0001). NSE levels in CSF were very strongly correlated with hemolysis index.
Biospecimens
FluidCerebrospinal FluidPreservation Types
None (Fresh)Diagnoses
Other diagnosesNot specifiedPlatforms
ProteinImmunoassayProteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Suspected neurodegenerative diseaseBiospecimen Aliquots and Components Biospecimen components 12-24.9 umol/L Hb25-35.9 umol/L Hb36-47.9 umol/L Hb<12 umol/L Hb>48 umol/L HbBiospecimen Aliquots and Components Hemolysis Hemolysate addedNo hemolysate addedStorage Storage duration 0 days1 month3 months6 months8 months9 monthsStorage Storage temperature -20 degrees C-80 degrees C
Purpose
The purpose of this study was to determine the effects of storage at -80 degrees C and hemolysis on the measurement of NSE in serum from patients suspected of having neuroblastoma or small cell lung cancer. Aliquots of serum were placed in polyethelene tubes for storage and recentrifuged before analysis. Hemolysate was prepared by lysing cells with toluene and water and vortexing.
Summary of Findings
NSE levels were unaffected by storage of serum at -80 degrees C. NSE levels in serum were very strongly correlated with hemolysis index.
Biospecimens
FluidSerumPreservation Types
None (Fresh)Diagnoses
NeoplasticCarcinomaNeoplasticOtherPlatforms
ProteinHematology/ auto analyzerProteinImmunoassayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Biospecimen components 12-24.9 umol/L Hb25-35.9 umol/L Hb36-47.9 umol/L Hb<12 umol/L Hb>48 umol/L HbBiospecimen Aliquots and Components Hemolysis Hemolysate addedNo hemolysate addedStorage Storage duration 0 days1 month3 months6 months9 months