Skip to main content

Interference of O.C.T. embedding compound with hormone receptor assays.

Muensch H, Maslow WC

Publication: Am J Clin Pathol (1984) • Vol 82 • Page 89-92PMID: 6741878View on PubMed

Purpose

The purpose of this paper was to determine if OCT embedding compound interferes with the dextran-charcoal method of assessing estrogen and progesterone receptor binding.

Conclusion

Although statistical significance was not assessed and between patient variability was high, estrogen receptor (ER) and progesterone receptor (PR) binding were reduced in all 22 breast tumor biopsies embedded in OCT prior to snap-freezing compared to un-embedded case-matched controls. The magnitude of difference in maximum binding potential (mean Bmax values) was greater for PR (OCT-embedded=10.6 fmol/mg, un-embedded control=109.6 fmol/mg) than ER (OCT-embedded=141.2 fmol/mg, un-embedded control=173.5 fmol/mg). OCT compound also induced an artifactual increase in color formation during the Lowry protein assay, as albumin standards that contained 4% OCT had a 20-25% higher absorption than those that did not.

Studies (1)

Purpose

The purpose of this study was to determine if OCT embedding compound can interfere with the receptor binding assays for ER and PR. ER and PR binding was quantified by the dextran charcoal method. Breast tumor specimens were divided and embedded in OCT or left untreated before being snap-frozen in liquid nitrogen and stored at -70 degrees C until analysis.

Summary of Findings

Although statistical significance was not assessed and between patient variability was high, estrogen receptor (ER) and progesterone receptor (PR) binding were reduced in all 22 breast tumor biopsies embedded in OCT prior to snap-freezing compared to un-embedded case-matched controls. The magnitude of difference in mean Bmax values was greater for PR (OCT-embedded=10.6 fmol/mg , un-embedded control=109.6 fmol/mg) than ER (OCT-embedded=141.2 fmol/mg, un-embedded control=173.5 fmol/mg). OCT compound also induced an artifactual increase in color formation during the Lowry protein assay, as albumin standards that contained 4% OCT had a 20-25% higher absorption than those that did not.

  • Biospecimens

    TissueBreast
  • Preservation Types

    OCTFrozen
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    ProteinReceptor binding
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    OCT
    Snap frozen
    Receptor binding SpecificTargeted peptide/protein
    ER
    PR