Quality Assessment of Biobanked Nucleic Acid Extracts for Downstream Molecular Analysis

Wahlberg K, Huggett J, Sanders R, Whale AS, Bushell C, Elaswarapu R, Scott DJ, Foy CA

Publication: Biopres and Biobank (2012) • Vol 10 • Page 266-275

Purpose

The purpose of this paper was to determine the effects of blood preservation and nucleic acid extraction method on DNA and RNA yield and integrity and on subsequent DNA analysis.

Conclusion

In general, the DNA yields were higher from PAXgene-preserved than citrate-phosphate dextrose (CPD) blood. The average DNA yield was highest when DNA extraction was from PAXgene blood with the PAXgene kit, and the variability in yield was also highest when the blood volume was small. DNA concentrations were significantly higher when measured by PicoGreen rather than spectrophotometer (p<0.0001), but the values were correlated. High molecular weight DNA was extracted from PAXgene blood using the Wizard kit, but other methods showed DNA fragmentation in at least some specimens. One sample of DNA extracted by Gentra and one sample extracted by PAXgene from PAXgene blood could not be used for calculation PCR of efficiency, but for the other specimens, the PCR efficiencies varied from 89.3%-109%. While the most efficient amplification was observed using the most degraded specimens (phenol/chloroform extracted DNA), a lower percentage of probes was detected in array comparative genomic hybridization (aCGH) using phenol/chloroform extracted DNA than DNA extracted using the other methods. The RNA yield was highest when RNA was extracted using the RiboPure blood kit, but the highest RNA integrity numbers (RINs) were achieved using the AllPrep kit and the PAXgene kits.

Studies (2)

Purpose

The purpose of this study was to determine the effects of using frozen CPD blood or PAXgene blood and DNA extraction method on DNA yield, integrity, real-time PCR amplification and aCGH analysis. CPD blood was stored at 4 degrees C for 2 days and then at -80 degrees C for 1-4 weeks, prior to thawing, aliquoting, and storage at -20 degrees C for up to 4 months. DNA was extracted from 3 0.3 mL CPD blood specimens using the Gentra Puregene or Wizard kits. Additional whole blood collected into PAXgene DNA tubes was purchased. DNA was extracted from 2-3 0.5 mL PAXgene blood specimens with Gentra, Wizard and PAXgene kits as well as phenol/chlorofom/isoamyl alcohol.

Summary of Findings

The DNA yields were similar between specimens extracted with the Gentra and Wizard kits, regardless of preservation method, but extraction of DNA from PAXgene blood with phenol/chloroform led to lower yields (p<0.0001). The average DNA yield was highest when DNA extraction was from PAXgene blood with the PAXgene kit, and the variability in yield was highest when the blood volume was small. The DNA yields were higher from PAXgene blood than CPD blood. DNA concentrations measured by PicoGreen and spectrophotometry were correlated (p<0.0001), but the concentrations were significantly higher when measured by PicoGreen (p<0.0001). High molecular weight DNA was extracted from PAXgene blood using the Wizard and PAXgene kits, but there was loss of DNA >40 kb when DNA was extracted from PAXgene or CPD blood using the Gentra Kit or from CPD blood with the wizard kit. Further, DNA extracted from PAXgene blood with phenol/chloroform was highly fragmented (<20 kb). Inter ALU amplification (iALU) PCR confirmed the fragmentation of phenol chloroform-extracted DNA from PAXgene blood and showed fragmentation of 1 of 2 PAXgene extracted specimens, but iALU PCR was successful for all other specimens. One Gentra-extracted DNA sample and 1 PAXgene-extracted DNA sample from PAXgene blood could not be used for calculation of efficiency, but for the other 18 specimens, the PCR efficiencies varied from 89.3%-109%. The highest R2 and PCR efficiency came from the most fragmented DNA (phenol/chloroform extraction). Regardless of DNA extraction method or preservation, all specimens had satisfactory dye incorporation in the aCGH assay, but only 66.53% of probes were detected using DNA extracted with phenol/chloroform from PAXgene blood. Using DNA extracted by any of the other methods, 82.79-91.94% of probes were detected in aCGH.

  • Biospecimens

    FluidBlood
  • Preservation Types

    FrozenPAXgene
  • Diagnoses

    Not specified
  • Platforms

    DNAArray CGH
    DNAElectrophoresis
    DNAFluorometry
    DNAReal-time qPCR
    DNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    PAXgene
    Analyte Extraction and PurificationAnalyte isolation method
    Gentra Puregene
    PAXgene
    Phenol/chloroform/isoamyl alcohol
    Wizard
    Real-time qPCR SpecificTargeted nucleic acid
    GAPDH
    Real-time qPCR SpecificTechnology platform
    aCGH
    Spectrophotometry SpecificTechnology platform
    PicoGreen
    Electrophoresis SpecificTechnology platform
    iALU PCR