Skip to main content

Overestimation of plasma level of factor V coagulant activity due to unrecognised preanalytical coagulation.

Eschwege V, Trillard M, Robert A

Publication: Thromb Haemost (2004) • Vol 91 • Page 827-8PMID: 15045150View on PubMed

Purpose

The purpose of this paper was to determine the effects of coagulation on prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen concentration, factor II, factor VII + X, and factor V levels in plasma.

Conclusion

Higher factor V levels were measured in plasma from clotted specimens than non clotted specimens. The increases in factor V levels ranged from 46-335%. PT, APTT, fibrinogen, factor II, and factor VII + X measurements were not affected by initially undetected preanalytical clots.

Studies (1)

Purpose

The purpose of this study was to determine the effects of coagulation on PT, APTT, fibrinogen, factor II, factor VII + X, and factor V levels in plasma. All specimens were collected in Vacutainers containing citrate. In an effort to evaluate the effects of initially undetected preanalytical clots, specimens with obvious preanalytical clots after centrifugation were not included in the study. Instead, after centrifugation, plasma from specimens with no obvious clots was transferred into new tubes, and the pellets were poured through a gauze swab. Specimens that had a visible clot at this point were included in the study as the clotted specimen (8/1334 or 0.6%), and a second specimen (non clotted) was drawn within 1 day of the first for comparison.

Summary of Findings

Higher factor V levels were measured in the plasma from clotted specimens than non clotted specimens. For the 8 specimen pais included in the study, the increases in factor V levels ranged from 46-335%. PT, APTT, fibrinogen, factor II, and factor VII + X measurements were not affected by initially undetected preanalytical clots.
  • Biospecimens

    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    MorphologyMacroscopic observation
    MorphologyHematology/ auto analyzer
    GlycoproteinHematology/ auto analyzer
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Clotted specimen